User's Manual
SatelLink
! USER MANUAL
DCM000000052
Printed: 01.05.11,14:10
Revision Date:5/11/01 13
Normal Operation
The SatelLink Head-End Module has one LED on the faceplate:
1. OPERATING - Normally this LED will be GREEN.
The SatelLink Remote Module has three LED’s on the faceplate:
1. OPERATING - Normally this LED will be GREEN.
2. FAULT – Red LED, If the internal diagnostics for the module detect a
problem, then this LED will remain on
3. LASERS ON - This LED will be GREEN when any one of the three Lasers
are operating.
Configuration
It is possible to re-configure the LNKFIB-R01 Remote Module in the field, either
with a Personal Computer (PC) or via the optional LinkNet Control Module. To
use a PC it is necessary to connect the DB9 RS-232 connector on the Module to a
standard DB9 RS232 Connector on the PC. On the PC a terminal emulation
program such as HyperTerminal is used to communicate to the LinkNet Module.
The settings are 9600 baud, 8 bits, no parity, and 1 stop bit. Commands are one or
two words followed by pressing Return. Commands may be given in upper or lower-
case. Available commands are...
ACCESS USER: Required as a simple password to gain access to customer
settable parameters and diagnostics; This will time-out after 10
minutes, and may have to be re-typed.
HELP or ?: Displays a list of Available Commands.
LIST: Displays Current Settings and Status Faults, Etc.
VER: Display the current Version of Software.
ENABLE 1 or 0: Enables or Disables the Module.
GAINPCS ###: Displays or Sets the PCS Transmit Gain (in tenths of a dB).
GAINCELL ###: Displays or Sets the Cellular Transmit Gain (in tenths of a dB).
GAINPAGE ###: Displays or Sets the iDEN and Paging Transmit Gain (in tenths of
a dB).
Please consult Kaval Wireless Technologies for further support.
Operation