Software Set-up
The LNKF800 module is shipped with the following factory set options:
OPTION RANGE OF VALUES DEFAULT VALUE
Frequency See Model Chart Order Specific
Receive Threshold
–110 to -50 dB -89 dB
Receive Hysteresis 1 to 10 dB 2.5 dB
Time Out 0 to 600 Seconds, or none 300 Seconds
Module Enabled On / Off On
Transmit Power Level 20 to 38 dBm Order Specific
Default values may be changed when an order is placed. Check your order
confirmation (shipped with modules) for customized values.
Configuration
In line with the versatility of the LinkNet
TM
Platform, it is possible to re-configure the
LNKF800 module in the field, either with a Personal Computer (PC) or via the
optional Control Module. To use a PC it is necessary to have a Kaval
CAB000000057 Control Cable to connect between the appropriate Module's DB15
connector on the back of the Card-Cage and the standard DB9 RS232 Connector on
the PC. On the PC a terminal emulation program such as HyperTerminal is used to
communicate to the LinkNet Module. The settings are 9600 baud, 8 bits, no parity,
and 1 stop bit. Commands are one or two words followed by pressing Return.
Commands may be given in upper or lower-case. Available commands are...
ACCESS USER: Required as a simple password to gain access to customer
settable parameters and diagnostics; This will time-out after 10
minutes, and may have to be re-typed.
HELP or ?: Displays a list of Available Commands.
LIST: Displays Current Settings and Status Faults, Etc.
VER: Display the current Version of Software.
ENABLE 1 or 0: Enables or Disables the Module.
TXFREQ #########: Displays or Sets the current Transmit Frequency (in Hertz).
RXFREQ #########: Displays or Sets the current Receive Frequency (in Hertz).
TXPOWER ###: Displays or Sets the Transmit Power Level (in tenths of a dBm).
RXTHRESH -####: Displays or Sets the Receive Threshold Level (in tenths of a dBm).
RXHYSTER ##: Displays or Sets the Receive Hysteresis (in tenths of a dB).
TIMEOUT ####: Displays or Sets the Timeout-Timer value (in Seconds).
TESTOSC 1 or 0: Enables or Disables the Test Oscillator.
Please consult Kaval Wireless Technologies for further support.