User's Manual
BDA1300 Equipment Manual
DCM000000018
Kaval Telecom Inc. Page 31 of 51
MAIN MENUS
Field Settings
Passwords
Defaults
Temperature
Backup Power
Fan Control
Downlink Power Amp.
Downlink Amplifier
Uplink Power Amp.
Uplink Amplifier
Field Settings Main Menu
The Field Settings main menu allows adjustment of the following submenu items:
Uplink Gain
Downlink Gain
Uplink AGC
Downlink AGC
Backup Power
Beep
Lamp Test
Factory (display only when the factory password is set)
Passwords Main Menu
This Menu allows the factory password settings. Once the password is set to anything but 0000
(default), only the Field Settings main menu is available for adjustment. A password submenu
called Factory will be available in the Field Settings. User will have access to all the main menus
when a correct Factory password is entered.
A second password level called Field Password will be available once the factory password is set
to anything but 0000 (default). When this Field Password is set to anything but 0000 (disabled),
user cannot access any Main Menu without entering the correct Field Password.
Backup Power Main Menu
This Menu allows the user to configure the BDA for backup power functionality.
If a battery is select in the Field Settings as backup power then this main menu category must be
programmed as follows:
Low Voltage: 24.0 (indicates voltage at which Warning is displayed)
Warn Voltage: 21.5 (voltage level at which imminent BDA shutdown is displayed as an
alarm)
Cutoff Voltage: 21.0 (voltage level at which battery back up is discontinued to prevent
battery damage)
Fan Control Main Menu
This menu has been programmed by the factory, based on the BDA configuration and
should not be accessed or modified.
This menu is used to configure the BDA cooling fans (if installed). Entry submenus include:
Fan Select: selects BDA fan configuration (available entries are NONE, A, B, BOTH)
Fan B min: indicates Fan B minimum operating current
Fan B max: indicates Fan B maximum operating current
Fan A min: indicates Fan A minimum operating current
Fan A max: indicates Fan A maximum operating current
If Fan A is selected then Fan B functions as a hot-switchover backup for Fan A