4 BDA1300 Models and Specifications
4.1 BDA1300 Specifications
RF Performance
Frequency Range 403 to 512 MHz
See model chart below
Passband Ripple ± 2.5 dB
Maximum Gain (nominal) 40 to 80 dB
See model chart below
Digital Gain Adjustment
16 or 32 dB
See model chart below
AGC Dynamic Range 25 dB
1 dB Compression Point
+35 dBm Typical
3rd Order Intercept Point IP3
+45 dBm Typical
Noise Figure
<12 dB
Propagation Delay
<5 µs
Impedance
50 ohms
VSWR
<2:1
Maximum RF Input
+10 dBm without damage
Electrical Specifications
Primary Voltage 120/230VAC +/- 10%, 50-60Hz
Primary Power 180 VA
Secondary Power
Two 12 VDC Sealed Lead -Acid Batteries, 10-100 AH
Battery Backup Time: Boosters only, 20 AH - 4 hrs Typical
Charge Time: 10 AH - Approx. 6 hrs, 100 AH - Approx. 48 hrs. Typical
Charge Current from BDA Controller is 3 Amps Maximum
The BDA will shut down for Battery Voltages below 21 VDC.
Consult Factory for more information.
Mechanical Characteristics
Dimensions W x H x D 17” x 16” x 10”
Weight 50 lbs. approx.
Housing Rugged Nema 4-Style Cabinet - Wall Mountable
Connectors N female
Operating Temperature Range
-30°C to +50°C
Humidity 95% RH Max, Non-Condensing
Type Acceptance
FCC Type Acceptance H6M-BDA1300
IC Type Acceptance TBD