Installation Instructions
• FIELD ADJUSTMENTS
The proper operation of the BDA in providing RF coverage extension is a function of not only the BDA, but also of
proper systems engineering including isolation measurements and in building RF distribution design. The most critical
requirement for the BDA installation is that the isolation between the “Roof-Top” Antenna and the in-building Antenna
distribution system exceed the overall BDA System Gain by at least 12dB. The actual gain requirement for each
Installation must be determined by the available antenna isolation and the operational requirements determined by
local Systems Engineering.
Each BDA has a Factory determined minimum gain both for the Uplink and Downlink Paths. The final Path Gain from
Antenna Port in to Antenna Port out, is set by the BDA Controller.
Follow through the BDA Controller Menus to set all configurable items as are appropriate for the installation.