User's Manual
Table Of Contents
- Front Page
- Contents
- Figures
- New Features in OMT32 Version R1A
- Abbreviations
- Part 1 – Hardware
- 1. Safety
- 2. Introduction
- 3. Installation
- 4. Commissioning
- 5. Functional Description
- Repeater Design
- Block Diagram
- Board and Unit Descriptions
- DC - Directional Coupler
- DPX - Duplex Filter
- LNA - Low Noise Amplifier
- CHA - Channel Amplifier Board for Channel Selective Operation
- CSA and PA Boards for Channel Selective CDMA Operation
- BSA and PA Boards for Band Selective Operation
- DIA Board
- CU Control Unit Board
- Repeater CU Software and Hardware Compatibility
- Cabling
- Part 2 – Software
- 6. OMT32 Installation
- 7. Help
- 8. Getting Started
- 9. OMT32 Features
- 10. Repeater Operations
- 11. Alarms and Events
- 12. Troubleshooting
- 13. Optional
- Appendix A - Menu Reference Guide
- Index
- Questionnaire
Alarm Text Alarm Unit Alarm Level Description
No BCCH detected RSSI Statistics Warning Signal strength on the BCCH channel was below the limit set
Ceasing The cause of the alarm has ceased
No connection Remote ctrl None No connection at callback
Warning No connection at alarm calling
No modem found Remote ctrl None No modem found
Ceasing Modem found
No phone detected Remote ctrl Warning When using a PC-card modem together with the MS this
alarm indicates contact with the PC-card modem but not
with the MS. The MS may be turned off.
Ceasing The cause of the alarm has ceased
PA fault BSA # Error Low power amplifier gain
CHA # Error Low power amplifier gain
CSA # Error Low power amplifier gain
Param. R/W error BSA # Error EEPROM failure on the BSA board
CHA # Error EEPROM failure on the CHA board
CSA # Error EEPROM failure on the CSA board
Modem PIN failed Remote ctrl Warning The PIN code sent tp MS is incorrect
Ceasing The cause of the alarm has ceased
Power supply PSU1 Critical Power failure in PSU1 (in the cabinet)
Ceasing PSU1 works properly again
PSU2 Critical Power failure in PSU2 (in the cover)
Ceasing PSU2 works properly again
PSU overvoltage BSA # Critical The PA supply voltage is too high
REFO error CU Error Significant REFO drift or error detected by CU
Remote connection Remote ctrl None Remote connection to OMT32 via modem
Remote link timeout Remote ctrl Warning Time limit of 20 min. exceeded without extending timer
Repeater restart CU None Powering up by user or after power failure
Warning Software restart error 1
st
- 7
th
time
Error Software restart error 8
th
- 10
th
time
RF blocking Chan. # UL Error Constant CW signal >27dBm. PA off.
Ceasing The cause of the alarm has ceased
RTC restarted CU None The time is changed by the operator
Warning Date set to 1994-01-01
RTC error CU Error RTC does not operate properly
Startup error BSA # Error Hardware error on BSA board
CHA # Error Hardware error on CHA board
CSA # Error Hardware error on CSA board
SW load error CU Error Software load error
Unsupported PA type CSA # Error Mounted PA board ID is not expected by the BSA board
Synthesizer fault BSA # Error Synthesizer unlocked on the BSA board
CHA # Error Synthesizer unlocked on the CHA board
CSA # Error Synthesizer unlocked on the CSA board
Volt Reg. fault BSA # Error Missing DC voltage on the BSA board
CHA # Error Missing DC voltage on the CHA board
CSA # Error Missing DC voltage on the CSA board
Remarks
1) The Door open alarm requires an optional door switch described in the P33 Alarm Port section in Chapter 3.
2) The Mains breakdown alarm requires a relay not included in the repeater (see Mains Breakdown Relay in Chapter 3).
Chan. #, UL/DL Repeater channel number (1-4) at channel selective operation, uplink or downlink.
BSEL #, UL/DL Repeater channel number at band selective operation, uplink or downlink.
CHA # CHA board number at channel selective operation.
CSA # CSA board number at channel selective CDMA operation.
BSA # BSA board number at band selective operation.
ALLGON System AB AR Repeaters & OMT32 Software – Alarms and Events
User’s Manual VD202 90/EN Rev. 1A 1999-07 11 - 15