User's Manual
Table Of Contents
- Front Page
- Contents
- Figures
- New Features in OMT32 Version R1A
- Abbreviations
- Part 1 – Hardware
- 1. Safety
- 2. Introduction
- 3. Installation
- 4. Commissioning
- 5. Functional Description
- Repeater Design
- Block Diagram
- Board and Unit Descriptions
- DC - Directional Coupler
- DPX - Duplex Filter
- LNA - Low Noise Amplifier
- CHA - Channel Amplifier Board for Channel Selective Operation
- CSA and PA Boards for Channel Selective CDMA Operation
- BSA and PA Boards for Band Selective Operation
- DIA Board
- CU Control Unit Board
- Repeater CU Software and Hardware Compatibility
- Cabling
- Part 2 – Software
- 6. OMT32 Installation
- 7. Help
- 8. Getting Started
- 9. OMT32 Features
- 10. Repeater Operations
- 11. Alarms and Events
- 12. Troubleshooting
- 13. Optional
- Appendix A - Menu Reference Guide
- Index
- Questionnaire
Alarm List
The following table contains the internal alarms which can occur and be
shown in the Repeater Event Log alarm window (additional alarms may
have been added to the system after issuing this manual).
Alarm Text Alarm Unit Alarm Level Description
Antenna isolation BSA # UL/DL Warning Poor antenna isolation
Error Poor antenna isolation at lowest gain
Ceasing The cause of the alarm has ceased
Chan. # UL/DL Warning Poor antenna isolation
Error Poor antenna isolation at lowest gain
Ceasing The cause of the alarm has ceased
Alarm reset CU None Manual alarm reset
Battery backup fault External Error Battery backup fault
Ceasing The cause of the alarm has ceased
CU battery fault CU Warning CU RAM battery fault
Ceasing The cause of the alarm has ceased
Door open alarm
1)
External Configurable Door open more than 30 seconds
Ceasing Door closed more than 30 seconds or the alarm is disabled
EEPROM error CU Error EEPROM read or write error
Ext REFO error CU Warning An external reference is lost (e.g. GPS reference)
External alarm 1 External Configurable External alarm input 1 active more than 1 second
Ceasing External alarm input 1 no longer active
External alarm 2 External Configurable External alarm input 2 active more than 1 second
Ceasing External alarm input 2 no longer active
External alarm 3 External Configurable External alarm input 3 active more than 1 second
Ceasing External alarm input 3 no longer active
External alarm 4 External Configurable External alarm input 4 active more than 1 second
Ceasing External alarm input 4 no longer active
Fiber Optical error External Configurable Fiber optic fault
Ceasing The cause of the alarm has ceased
Gain reduction Chan. # UL/DL Warning The gain is reduced below the limit
Ceasing The cause of the alarm has ceased
High temperature BSA #
CHA #
CSA #
Warning The board temperature is higher than 85°C
Error The board temperature is higher than 95°C
Ceasing The board temperature has fallen below 70°C
CU Warning The CU board temperature is higher than 90°C
Ceasing The CU board temperature has fallen below 90°C
Local bus error BSA # Error Communication bus error on BSA board
CHA # Error Communication bus error on CHA board
CSA # Error Communication bus error on CSA board
Log cleared CU None Log memory has been cleared
Log memory fault CU Error Log memory fault
Logon failed CU None Invalid repeater password
Low traffic activity RSSI Statistics Warning No signal strength was above the limit set
Ceasing The cause of the alarm has ceased
Mains breakdown
2)
External Critical Power failure
Ceasing Mains power is up again
Mains bkd w backup External Error Mains breakdown - power from battery backup
Ceasing The cause of the alarm has ceased
Modem init failed Remote ctrl None Initiation string to modem not OK
ALLGON System AB AR Repeaters & OMT32 Software – Alarms and Events
User’s Manual VD202 90/EN Rev. 1A 1999-07 11 - 14