User's Manual

Table Of Contents
Repeater Modem Parameters
The command string, the PIN code to the repeater modem, and the
modem transfer speed can be set in the following dialog box, which is
opened by selecting the Modem option in the Repeater Preferences
menu.
Repeater modem init string
In this field you can set the modem initiation string.
Be careful not to set an incorrect string at remote control of the repeater.
A visit to the repeater site may be the result, and you will get no alarm call
until a correct string has been entered. The default string should not be
changed.
Modem PIN code
If a PIN code is to be used for the repeater mobile phone, enter the PIN
code in this field. Otherwise, leave this field blank.
Modem speed
The modem transfer speed in bps (baud rate) for the repeater modem.
Default value is 19200.
This field is available only when OMT32 is locally connected to a repeater.
Detected modem
Shows the modem type the repeater CU software has detected and
recognized.
Update
Click the Update button to download the modem information to the
repeater.
Figure 10-35. Repeater modem parameters
ALLGON System AB AR Repeaters & OMT32 Software – Repeater Operations
User’s Manual VD202 90/EN Rev. 1A 1999-07 10 - 50