User's Manual

Table Of Contents
1
. Safety
Any personnel involved in installation, operation or service of the Allgon
repeaters must understand and obey the following:
Allgon repeaters are designed to receive and amplify signals from one or
more base stations and retransmit the signals to one or more mobile
stations. Also, the repeaters are designed to receive signals from one or
more mobile stations, amplify and retransmit to the base stations. The
repeaters must be used exclusively for these purposes and nothing else.
Repeaters supplied from the mains must be connected to grounded
outlets and in conformity with any local regulations.
The power supply unit in repeaters supplied from the mains contains
dangerous voltage level, which can cause electric shock. Switch the
mains off prior to any work in such a repeater. Any local regulations
are to be followed when servicing repeaters.
Authorized service personnel only are allowed to service repeaters while
the mains is switched on.
The repeater cover must be secured in opened position, e.g. by tying it
up, at outdoor repeater work. Otherwise, the cover can be closed by the
wind and cause your fingers getting pinched or your head being hit.
When working on a repeater on high ground, e.g. on a mast or pole, be
careful not to drop parts or the entire repeater. Falling parts can cause
serious personal injury.
Any repeater, including this repeater, will generate radio signals and
thereby give rise to electromagnetic fields that may be hazardous to the
health of any person who is extensively exposed to the signals at the
immediate proximity of the repeater and the repeater antennas.
BERYLLIUM OXIDE
The CHA channel board power transistors, the PA amplifier board
power transistors, and the combiners (CMB) contain beryllium oxide
(BeO) that is poisonous if present as dust or smoke which can be
inhaled. The power transistors mentioned are mounted with two
screws as opposed to other transistors.
Do not file, grind, machine, or treat these parts with acid.
Warning signs are applied on boards and units that contain beryllium
oxide. These warning signs are shown in the next section.
HYDROGEN FLUORIDE
The coaxial cable insulation is made of PTFE, polytetrafluoro ethylene,
that gives off small amounts of hydrogen fluoride when heated.
Hydrogen fluoride is poisonous. Do not use heating tools when
stripping off coaxial cable insulation.
No particular measures are to be taken in case of fire because the
emitted concentration of hydrogen fluoride is very low.
A lithium battery is permanently mounted on the CU board. Due to
the risk of explosion, this battery must not be removed from the board.
In case of battery malfunction, replace the CU board. The old CU
board can be sent to Allgon for repair.
ALLGON System AB AR Repeaters & OMT32 Hardware – Safety
User’s Manual VD202 90/EN Rev. 1A 1999-07 1 - 1