User's Manual
Table Of Contents
- Front Page
- Contents
- Figures
- New Features in OMT32 Version R1A
- Abbreviations
- Part 1 – Hardware
- 1. Safety
- 2. Introduction
- 3. Installation
- 4. Commissioning
- 5. Functional Description
- Repeater Design
- Block Diagram
- Board and Unit Descriptions
- DC - Directional Coupler
- DPX - Duplex Filter
- LNA - Low Noise Amplifier
- CHA - Channel Amplifier Board for Channel Selective Operation
- CSA and PA Boards for Channel Selective CDMA Operation
- BSA and PA Boards for Band Selective Operation
- DIA Board
- CU Control Unit Board
- Repeater CU Software and Hardware Compatibility
- Cabling
- Part 2 – Software
- 6. OMT32 Installation
- 7. Help
- 8. Getting Started
- 9. OMT32 Features
- 10. Repeater Operations
- 11. Alarms and Events
- 12. Troubleshooting
- 13. Optional
- Appendix A - Menu Reference Guide
- Index
- Questionnaire
Command List
Main Command Command/Parameter/Sample Description
OM OM-EXIT Exits the OMT32 program
General OMT32 program Parameter: [NOW] No confirmation
Ex.: OM-EXIT; Exit after confirmation
Ex.: OM-EXIT: NOW; Exit without confirmation
TIME TIME-WRT Time setting
Internal repeater clock date and
time
Parameter: HH.MM.SS Hour-Minute-Second
Ex.: TIME-WRT: 13.25.30; Time setting: 13:25:30
TIME-WRD Date setting
Parameter: YYYY-MM-DD-WW[W...] Year-Month-Day-Weekday
Ex.: TIME-WRD: 1999-07-12-MON; Date setting 1999-07-12-Monday
PAR PAR-COMBATT Uplink/downlink combiner attenuation
Parameters and repeater ID Parameter 1: U[P]/D[OWN Uplink/Downlink
Parameter 2: value Combiner attenuation value
Ex.: PAR-COMBATT: U, 6; Uplink combiner attenuation 6dBm
PAR-CHAN Links a repeater channel to a GSM/CDMA
channel
Parameter 1: # Repeater channel number (1-4)
Parameter 2: # GSM/CDMA channel number
Ex.: PAR-CHAN: 2, 116; Repeater channel #2 is linked to
GSM/CDMA channel #116
PAR-CHACT Turns a repeater channel on/off
Parameter 1: # Repeater channel number (1-4)
Parameter 2: ON/OFF Channel on/off
Ex.: PAR-CHACT: 3, ON; Repeater channel #3 on
PAR-GAIN Uplink or downlink channel gain
Parameter 1: # Repeater channel number (1-4)
Parameter 2: U[P]/D[OWN Uplink/Downlink
Parameter 3: value Gain value
Ex.: PAR-GAIN: 4, D, 34; Repeater channel #4 downlink 34dB gain
PAR-REPID Connected repeater is assigned a new ID
string
Parameter: string ID for the connected repeater
Ex.: PAR-REPID: new; Connected repeater ID = ’new’
BSA BSA-GAIN Uplink or downlink gain
Band selective parameter Parameter 1: U[P]/D[OWN Uplink/Downlink
Parameter 2: value Gain value
Ex.: BSA-GAIN: DOWN, 36; Downlink gain 36dB
BSA-FREQ Uplink or downlink frequency
Parameter 1: U[P]/D[OWN] Uplink/Downlink
Parameter 2: value (12.5KHz steps) Frequency in MHz
Ex.: BSA-FREQ: UP, 890.5; Uplink frequency 890.5 MHz
BSA-AGC Uplink or downlink Automatic Gain
Control on/off
Parameter 1: U[P]/D[OWN] Uplink/Downlink
Parameter 2: ON/OFF Automatic gain control on/off
Ex.: BSA-AGC: D, ON; Downlink AGC on
BSA-PAON Uplink or downlink PA board on/off
Parameter 1: U[P]D[OWN Uplink/Downlink
Parameter 2: ON/OFF PA board on/off
Ex.: BSA-PAON: UP, OFF; Uplink PA off
ALLGON System AB AR Repeaters & OMT32 Software – OMT32 Features
User’s Manual VD202 90/EN Rev. 1A 1999-07 9 - 7