Testpoints
Testpoint Voltage Purpose
U7A +7V DC CHA1/DL or CSA/DL or BSA/DL downlink
board supply voltage.
U7B +7V DC CHA2/DL or PA/DL downlink board supply
voltage.
U7C +7V DC CHA3/UL or CSA/UL or BSA/UL downlink
board supply voltage.
U7D +7V DC CHA4/UL or PA/UL downlink board supply
voltage.
U7E +7V DC LNA/UL and LNA/DL and P27 auxiliary port
supply voltage.
U7F +7V DC CU board and ALI board and RCU supply
voltage via the P27 auxiliary port jumper.
U26 +26V DC
or
+13V DC
or
+10V DC
Power amplifiers and P27 auxiliary port supply
voltage (26V, 13V or 10V depending on the
repeater type).
GND 0 Ground
DIA board part # and version
The DIA board part # is K105/1. Version R2A or higher (containing the
P34 connector) is required to use the optional Repeater to Repeater Link
feature.
Functional Description AR Repeaters ALLGON System AB
5 - 24 Rev. P1A 2000-09 User’s Manual VD203 66/EN