User's Manual
Table Of Contents
- Front Page
- Preface
- Contents
- Figures
- Abbreviations
- 1. Safety
- 2. Introduction
- 3. Installation
- 4. Commissioning
- 5. Functional Description and Design
- 6. Optionals
- 7. Repeater Alarms
- Index
- Questionnaire
ID Alarm Text OMS
Ceasing
Alarm Unit Alarm Level Description
55
R2R queue full
No BSC
None
The R2R transmitting queue is full and messages are lost.
Suggested remedy: Check the R2R configuration and cables.
56
R2R node lost
No BSC
None
An R2R node is lost.
Suggested remedy: Check if the node is still operating and
connected.
57
R2R HW error
No BSC
Error
R2R hardware fault.
Suggested remedy: Replace the repeater.
70
Bad table found
No BSC
Error
A requested table contains information error (software error).
71
Table not found
No BSC
Error
A requested table was not found in the database (software or
calibration error).
72
Table database
err
No BSC
Error
The database table is not found (calibration error).
121
Synthesizer fault
Yes BSC UL/DL
Error
Unlocked synthesizer.
The frequency synthesizer is unlocked and the transmission can
take place on unknown frequency.
122
Volt Reg fault
Yes BSC UL/DL
Error
A DC voltage to an analog part of the board is missing.
123
PA fault
Yes BSC UL/DL
Error
Low power amplifier gain.
The PA has too low output power for the RSSI and gain set.
Not available in all BSC software versions.
125
High temperature
No BSC UL/DL
Warning
The BSC board temperature is higher than 85°C.
Error
The BSC board temperature is higher than 95°C and the power
is turned off.
Ceasing
The temperature has fallen to below 70°C and the power is
turned on again.
126
High PSU
voltage
Yes BSC UL/DL
Critical
The PA supply voltage is too high.
Suggested remedy: Ensure that correct PSM is used.
Remarks
The Mains breakdown alarm (3) requires a relay not included in the repeater.
The Door open alarm (20) requires an optional door switch.
The Battery backup fault alarm (48) requires an optional battery backup unit.
The Fiber optical error alarm (50) requires an optional fiber optical interface.
ALLGON Systems AB ALR Compact Repeater Repeater Alarms