User's Manual

P124 Repeater to Repeater Link Port
P124 is used for the Repeater to Repeater Link feature (R2R net).
P124 is a 5 pole male connector located to the right in the cabinet,
adjacent to the P118 connector (see Figure 3-7).
The usage of P118 and P124 is described on page 3-10.
P120 Door Switch
P120 is used for repeater door alarm. An internal door switch is
connected to this port to activate door alarms.
P120 is a 3-pole male connector located in the center of the cabinet,
adjacent to the P119 alarm connector (see Figure 3-7).
The alarm level for this input is always Warning w ceasing.
This alarm input is separated from the alarm inputs in the P119 alarm
connector. The EAL4 in the P119 alarm port (pin 6) can also be
configured as door alarm input with settable alarm level.
The door switch alarm is activated 30 seconds after the door switch has
been activated.
Connector pinning
Pin 1 Ground
Pin 2 Alarm input
Pin 3 Power (5V, 10mA for the door alarm circuitry)
15
P130 RCC Port
The P130 RCC port is used for connecting an RCC mobile phone/modem
remote control unit.
P130 is a 34 pole 2 line male connector located to the right in the cabinet
(see Figure 3-7).
The P130 connector contains modem/telephone line connection, RCC
power supply, etc.
If there is no RCC remote communication control unit connected to the
P130 port, then pin 1 and pin 2 must be interconnected with a jumper
(see P113 on page 3-10).
Pin 1 and 2 of the P130 port MUST ALWAYS be interconnected to provide
voltage supply to a part of the repeater circuitry.
1
3
12
33 34
ALLGON Systems AB ALR Compact Repeater Installation
VD203 67/EN - User’s Manual Rev. 1A 2000-07 3 - 12