User's Manual

To get the repeater to meet these regulations, select one of the
following classified and approved cord types:
EN - H 05 W5 - F HMR
UL - AWM Style 2587
CSA - AWM 1 A/B 11 A/B
For outdoor use the power cord should meet at least IP65
encapsulation requirements.
The repeater PSM must be grounded. Make sure the ground cable
part is connected to ground in the PSM connector.
Ground is marked with the following symbol:
3. Connect external alarm sensors (burglary, fire, etc.) and other
external alarm equipment (optical or acoustic signal, etc.), if any.
Cables for this installation is taken through a free strain relief
bushing at the bottom of the repeater, in the same way as the mains
cable and the antenna cables.
External alarm is connected to the P119 alarm port located in the
center of the cabinet (see Figure 3-7 on page 3-9). Use a 7 pole
female connector.
The P119 port is described on page 3-11.
4. Connect the Repeater to Repeater Link cable, if this feature is to be
used. The R2R net cable is connected to the P118 or P124 Repeater
to Repeater Link ports to the right in the repeater. Connection and
termination is described on page 3-10.
Any cable type can be used for indoor installation.
The following cable type is recommended for outdoor installation:
Li 2YC11Y, 2x2xAWG24/222, non-halogen, Metrofunkkabel-Union.
If the link cable between two repeaters in an R2R net is longer than
25 meters, then an RS-485 repeater is required, see the figure.
Free strain relief bushings at the bottom of the repeaters are used for
the external net cables.
The P118 and P124 Repeater to Repeater Link ports are described on
page 3-10 and page 3-12.
ANT
HI LO
ANT
LO
HI
P119
External
alarm sensors
ANT
HI LO
ANT
LO
HI
P118
ANT
HI LO
ANT
LO
HI
P118
ANT
HI LO
ANT
LO
HI
P118
ANT
HI LO
ANT
LO
HI
P118
>25m
ALLGON Systems AB ALR Compact Repeater Installation
VD203 67/EN - User’s Manual Rev. 1A 2000-07 3 - 7