The APDU can be installed both indoors and outdoors. It is mounted in a
environmentally protected (IP 65) lockable box, and can be mounted without any
kind of protection from bad weather conditions. However, it is not permitted to install
the APDU outdoors in bad weather conditions. If the bad weather conditions are of a
short duration, and the APDU and all other connectors that are to be connected during
the installation are protected, the installation may continue not less than one hour after
the adverse conditions have ended.
Information on environmental requirements for the APDU is found in the Reference
Manual.
Dimensions
Figure x: APDU box (dimensions 200x300x150mm)
Mounting equipment
The APDU is mounted on the same kind of mounting plate as the TTPA. Check the
TTPA mounting instructions for how to attach the mounting plate to the wall, and the
ADPU to the mounting plate.
Checklist before mounting and installation
Check that the CI (Current Injector) is of the right type. Note that the TTPAs and
TTAs must be connected with different CIs:
TTA: 8478.xx, 8484.xx, 9184.xx or 9221.xx, for 12 VDC
TTPA: 9219.xx, for 48 VDC
Is 48VDC or 115/230 VAC supply available?
Does the supply cable for the APDU have the correct connector on the BTS side?
Are the correct cables with the correct connectors between APDU and Current
Incector available and are they long enough?
Is the necessasy equipment and material to connect the alarm cable to the BTS
external alarms available?
Is the alarm cable of the correct type?
Are a ground wire or heavy duty crimp terminals, cable and a crimp tool
available?
Are the 7/16 connectors to be connected to the CI of the correct sex?
Are the DMM, cable ties and all the necessary tools available?
Installation procedure for APDU in BTS
Before the actual installation is started, read the safety information at the beginning of
this guide.
Phase 1: This part of the installation can be carried out without switching off the
BTS.