User's Manual
Commissioning Nexus FT RMR
3-4 044-05326 Rev B
Commissioning
Before proceeding, carefully read the Safety section and check all connections made during the installation.
Ensure cables are properly tightened and not damaged.
The RMR can be configured locally with OM-Online by connecting a standard serial cable from the COM port
on the PC to the P31 PC port (RS-232) located on the front of the RMR. Details on using OM-Online are
described in the OM-Online User Manual - Connecting a PC for Local Access
Initial Startup
To complete the initial start-up of the Nexus FT RMR, follow the steps listed in Table 3-4.
Table 3-3 Initial Statup Procedure
NOTE: When optimizing RMRs, offset the UL gain 20 dB less than the DL gain as a starting point.
Always monitor the UL pass bands for noise levels and/or IMDs when optimizing and commission-
ing.
Step Action
1 Turn main power on.
2 Check the LEDs on the RMR. Refer to Figure 2-1 in Chapter 2 for correct power up indications.