Maximum Current Draw (Single Band) 6.5 A @ 115 VAC
3 A @ 230 VAC
Maximum Current Draw (Dual Band) 6 A @ 115 VAC
3 A @ 230 VAC
Recommended Fuse size 10 A for AC voltage
20 A for AC voltage
Power consumption 420 W typical, 600 W max
Impedance
Input
Output 50 Ω
Mechanical
Dimensions (W x H x D in inches) 484 x 153 x 580 mm (19 x 6 x 228.4 in)
Weight <45 kg (100 lbs)
Service Antenna port connector Female N-Type
Donor port connector SMA
Environmental
Operating Temperature Range -25 °C to +55 °C (-13°F to +131°F)
Altitude -142 m to 4000 m (-466 ft. to 13100 ft.
Casing class NEMA4/IP65
Fiber Optic Node (FON)
Bandwidth @ 3dB 800 – 2200 MHz
Power Consumption, total <5 W
Wavelength TX: DFB 1310 or 1550 nm
RX: 1250 – 1600 nm
Transmit
Max continuous RF input
RF attenuation settable by SW in 1dB steps
+36dBm
0-20dB
Receive
Max optic power input
RF attenuation settable by SW in 1dB steps
Alarm threshold level, settable warning
Alarm threshold level, settable error
+5dBm
4-24dB
0-40dBm
0-40dBm
Table 5-1: RMR Specifications (Continued)