User's Manual
044-05251 Rev C 5-1
Chapter 5
Specifications
Introduction
This chapter provides specifications for the WRH.
Table 5-1: WRH Specifications
Electrical
Frequency band UL 788 to 805 MHz (CS, PS)
824 to 849 MHz (Cellular)
806 to 824 MHz (800 iDEN)
880 to 915 MHz (GSM 900)
896 to 901 MHz (900 iDEN)
1710 to 1785 MHz (GSM 1800)
1850 to 1910 MHz (PCS)
1850 to 1915 MHz (PCS+G)
1920 to 1980 MHz (UMTS)
1710 to 1755 MHz (AWS 2100)
Frequency band DL 758 to 775 MHZ (CS, PS)
869 to 894 MHz (Cellular)
851 to 869 MHz (800 iDEN)
935 to 940 MHz (GSM 900)
925 to 960 MHz (900 iDEN)
1805 to 1880 MHz (GSM 1800)
1930 to 1990 MHz (PCS)
1930 to 1995 MHz (PCS+G)
2110to 2170 MHz (UMTS)
2110 to 2155 MHz (AWS 2100)
Max absolute delay <300 ns
Gain adjustment range (in 1 dB steps) 30 dB
Gain
Uplink
Downlink
Variation
35 to 60 dB typical - Excluding fiber link
45 to 70 dB typical - Excluding fiber link
± 1.5 dB versus temperature including fiber link
± 1.5 dB versus DL frequency including fiber link
± 0.5 dB versus DL output power including fiber link
± 0.5 dB versus input voltage including fiber link
± 2.0 dB versus UL frequency including fiber link
Instantaneous bandwidth 17 MHz (CS, PS)
25 MHz (Cellular)
18 MHz (800 iDEN)
35 MHz (GSM 900)
5 MHz (900 iDEN)
75 MHz (GSM 1800
60 MHz (PCS)
65 MHz (PCS+G)
60 MHz (UMTS)
45 MHz (AWS)