User's Manual

Initial Start-up and Operating Procedures G3L-2129-140 MCPA
3-2 044-05369 Rev A
Figure 3-1 MCPA Quarter-turn fasteners and Connectors
Initial Start-up and Operating Procedures
Perform the MCPA initial start-up per the instructions in Table 3-3.
CAUTION: Before applying power, ensure input and output cables are properly terminated at the
Duplexer front panel. Do not operate MCPA without a load attached. Excessive input power may
damage the MCPA. Refer to Chapter 5 for input power requirements.
Table 3-2 MCPA Installation Steps
Step Action
1
Set MCPA OFF/ON/RESET switch to the OFF (down) position.
2
Ensure quarter-turn fasteners are in unlocked position.
3
Lift and insert MCPA into the subrack. Turn the quarter-turn fasteners to locked
position to secure MCPA into subrack.
Table 3-3 MCPA Start-up Steps
Step Action
1
Verify all system input and output cables are properly connected.
2
Verify +27 VDC (+/- 1 VDC) supply is available.
3
Set MCPA OFF/ON/RESET switch to ON (center) position.
4
Allow MCPA to warm-up for a minimum of two minutes before taking power
readings.
RF Switch:
RJ-11
Connector
(Factory use only)
Quarter-turn
fastener
RESET
ON
OFF
Quarter-turn
fastener
Interface
Connector
Unlocked
Locked
DRAFT