Status – Dynamic
This page displays the current status of the system. The items displayed are not editable and are for
information only.
Figure 3-17 Status - Dynamic page
State
• DEGRADE = Minor system fault Fan / Intrusion / ……
• PASS = Enabled and no faults
• FAIL = Faulted (see the STATUS – ALARM page for details)
• MISSING = Sector is Enabled with missing components, critical sector alarm state.
Temperature – Display of real time temperature sensors for the main system components.
Forward Power – The output power detected at the TX/RX ANT Port for each sector in Watts.
Reverse Power - The reverse power detected at the TX/RX ANT Port for each sector in Watts.
Return Loss – Real-time measurement of the return loss at the TX/RX ANT Port in dB.
TMA Main – Each TMA channels current draw in mA.
TMA Diversity – Each TMA channels current draw in mA.
Alarm Summary – MINOR, MAJOR, CRITICAL status for each sector or system. See the Status – Alarm page
for details
MCPA APC
• OFF — No APC
• ON — APC active and gain display is in accurate and channel is overdriven. Reduce input source or
reduce sector gain.
MCPA Front Panel Switch
• OFF — MCPA disabled via the front panel switch
• ON — MCPA front panel switch is on.
Rectifiers – Installed
• YES — Alarm reporting for this channel is enabled.
• NO — Alarm reporting is disabled for this rectifier channel.
Rectifiers – Comm Status
• Comm — Rectifier module installed, alarm reporting enabled and no faults