User's Manual Part 3

Controller Web Pages OS-1933-E3-003
044-05243 Rev A 3-13
Installed – Allows sector configuration. Select YES for sectors to be active, choose NO for sectors to
remain vacant. Choose SUBMIT to accept the changes to the page. Initial default is enabled.
Tx Gain – Allows sector’s TX gain adjustment. Type in the desired gain value in 0.1 dB steps.
Choose SUBMIT to accept the changes to the page. Initially set to 5.0dB.
LNA Gain - Allows sector’s LNA gain adjustment. Type in the desired gain value in 0.5 dB steps.
Choose SUBMIT to accept the changes to the page. One LNA Gain value per sector applies to the
main and diversity LNA channels. Initially set to 0.0dB.
TMA Main – Controls the operation of the Main TMAs. Choose ENABLE for TMA use and DISABLE
to suspend TMA use. Choose SUBMIT to accept the changes to the page. Initial default is dis-
abled.
TMA Diversity – Controls the operation of the Diversity TMAs. Choose ENABLE for TMA use and
DISABLE to suspend TMA use. Choose SUBMIT to accept the changes to the page. Initial default
is disabled.
VSWR Alarm LL – Allows configuration of the VSWR Alarm threshold. The range is 0.0 to 12.0.
Adjustment does not alter protection shutdown thresholds.
RECTIFIERS – Controls alarm reporting for each rectifier module (4-total). Configuration does not
effect the operation of the rectifier modules. The rectifier modules are plug n’ play, if they are
inserted with a green LED they are operating. Choose YES for every inserted module to ensure
proper alarm reporting. Choose NO for vacant rectifier slots. Choose SUBMIT to accept the changes
to the page. Initial default is YES. Vacant rectifier slots should be plugged with blank panels to opti-
mize thermal characteristics of the system.
External Alarms – The system has the capability to detect four form-c inputs. The configuration
allows the each of the four alarms to be configured individually. Choose OFF (default) to disable an
alarm channel. Choose NO (Normally Open) to receive a normally open form-c alarm. Choose NC
(Normally Closed) to receive a normally closed form-c alarm. Received faults will assert a system
Major alarm. Choose SUBMIT to accept the changes to the page.
Status – Static
This page displays the current configuration of the system. The items displayed are not editable and are for
information only.
Figure 3-16 Status - Static page
• Installed – Installed sectors are Yes. Disabled sectors are No.
• Firmware – System and MCPA firmware versions.
• Tx1 Gain – Displays the Tx1 gain setting for each sector.
• Tx2 Gain – Displays the Tx2 gain setting for each sector.
• Tx3 Gain – Displays the Tx3 gain setting for each sector.
• Tx4 Gain – Displays the Tx4 gain setting for each sector.
• LNA Gain – Displays a LNA gain setting for each sector, showing the main and diversity channels.
• TMA Main – Displays the status of each channel.
• TMA Diversity – Displays the status of each channel.