User's Manual Part 3

Alarm Functions OS-1933-E3-003
044-05243 Rev A 3-17
Ethernet Web Page Procedure
Ethernet Interface (rear panel)
This port is intended for control and monitoring by a BTS or Remote Network Management System on a
permanent basis.
Form-C / External Alarm Interface (rear panel)
Reference the Form-C and External Alarm interface section in chapter 2 for pin-outs and installation.
Form-C Alarms
The alarm status is reported via Form-C contacts. There are five Form-C alarms: ALARM1 through ALARM5.
The alarms are detailed as follows:
Alarm 1
Minor Alarm - all sectors:
• Any cabinet fan fault.
• Intrusion – if one or both booster doors are opened.
• Rectifier Communication Fault.
Alarm 2
A Major Alarm - all sectors:
• TMA1 or TMA2 is faulted (if both enabled), but not both faulted.
• TMA3 or TMA4 is faulted (if both enabled), but not both faulted.
• TMA5 or TMA6 is faulted (if both enabled), but not both faulted.
• LNA1 or LNA2 is faulted, but not both faulted.
• LNA3 or LNA4 is faulted, but not both faulted.
• LNA5 or LNA6 is faulted, but not both faulted.
• Any rectifier fault.
• Any External Alarm fault.
• No communication from the MODEM (if applicable).
Table 3-15 Ethernet Web Procedure
Step Action
1
Connect Ethernet crossover cable from PC to modem front panel ETHERNET connector.
2
Boot up PC.
3
On PC, go to Start-Settings-Control Panel Network Connections. Right click on Local Area Connection,
then select Properties.
4
After Local Area Connection Properties window opens, deselect all functions except Internet Protocol
(TCP/IP).
5
Double click on Internet Protocol (TCP/IP) to open Internet Protocol (TCP/IP) Properties window.
6
Select “Use the following IP address”.
7
At “IP address” type in 192.168.0.2, then press Tab key. Subnet mask fills in 255.255.255.0. Select OK to
close window.
8
Select OK to close Local Area Connection Properties window.
9
Open Internet Explorer.
10
Using Internet Explorer Address bar, type http://192.168.0.1, then press Enter key. The Powerwave
Twoport application is enabled and Log In screen is displayed.