User's Manual Part 3
OS-1933-E3-003 OS System Configuration
3-6 044-05243 Rev A
Activate Rectifier Modules
Activate TMA Channels (2 per Sector)
CAUTION: This parameter sources +12 V at 500 mA maximum to antenna ports. Caution should be used
if antenna ports are connected to test equipment with 0 VDC tolerance.
To prevent a short circuit and alarm situation, all antenna port connections must be complete prior to
enabling TMA DC supplies.
NOTE: These configurations enable DC voltage at antenna ports and enable RX fault monitoring.
Each Rx channel sources +12 V at 500 mA maximum. Any current less than 40mA will generate a LO
CURRENT fault. Any current greater than 150mA will generate a HI Current fault. Any current greater than
500 mA will disable the DC source for that channel and generate a HI CURRENT fault.
A HI CURRENT condition attempts to auto-recover every five minutes by enabling the DC to Rx channel. If
fault condition is cured, alarm clears and source remains on. If fault is present, there is no change in sta-
tus.
Table 3-4 Activate Rectifier Modules
Step Action
1 Select the System/Configuration Page. See Figure 3-15.
2 Using the pull-down menus in the Rectifier/Installed section, choose YES to activate the
Rectifier Modules. Reference the rectifier positions detailed on the front rack ears of the
power system. Default is NO.
3 Choose SUBMIT to accept and apply the changes. To abort changes choose another page
without applying submit.
Table 3-5 Activate TMA Channels
Step Action
1 Select the System/Configuration Page. See Figure 3-15.
2 Using the pull-down menus in the TMA Main/Diversity sections choose ENABLE for the
TMAs to be utilized. Default is DISABLED
3 Choose SUBMIT to accept and apply the changes. To abort changes choose another page
without applying submit.
4 Navigate to the Status / Dynamic page. See Figure 3-17.
5 Verify the correct TMA channels have the correct current draw per the specifications of the
TMA. Currents less than 40mA or greater than 150mA will assert a fault. Currents greater
than 450mA will crowbar the power source. The system will retry every 5-minutes to enable
the channel in the event the short is remedied. A crowbar can also be reset by configuring
the channel disabled and then enabled.