External Alarms
The OS booster is capable of monitoring and reporting external Form-C alarms. Four channels are provided
and each channel is programmed via the Controller Module for NO or NC conditions. For example, NO will
fault when shorted to Common (C) and NC will fault when open to Common (C).The four channels are mapped
to Form-C alarm outputs configured as such via the Ethernet web pages.
(1) Could be critical and bypass if both Rx channels are faulted.
(2) If enabled.
Table 1-1 Faults
Control Module Display X = Form-C
Fan XX Fault FT(front)/
RT(frear)
Minor
RFCU Fault (3) Sector 1 - 3 Critical
Bypassx DC Fault (3) Sector 1 - 3 Critical
LNA 1 Fault
LNA 2 Fault
Sector 1 - 3 Major (1)
Rect Comm Fault Minor
Rect VAC High Major
Rect VAC Low Major
Rect VDC High Major
Rect VDC Low Major
Rect Current Limit Major
Rect Fault (not all) Major
Rect Fault (all) Critical
No MCPA Sector 1 - 3 Critical
MCPAX VSWR Sector 1 - 3 Critical
MCPAX Loop Sector 1 - 3 Critical
MCPAX Ovr Pwr Sector 1 - 3 Critical
MCPAX Hi Temp Sector 1 - 3 Critical
MCPAXInt DC Sector 1 - 3 Critical
MCPAX Ext DC Sector 1 - 3 Critical
Ext Alarm0 Major (2)
Ext Alarm1 Major (2)
Ext Alarm2 Major (2)
Ext Alarm3 Major (2)
TMA1 Hi Current Major (1)
TMA 1 Lo Current Major (1)
TMA 2 Hi Current Major (1)
TMA 2 Lo Current Major (1)