User's Manual

Connections Nexus FT Strand Mount
3-2 044-05320 Rev A
Connections
This section describes general examples of how to connect the input and output ports on the WRH.
Main Power and Grounding
Local regulations need to be followed for the main power connection. Nexus FT SMs are approved in
accordance with EN and UL/cUL regulations. This is, however, only valid if a classified power cord is used.
For the Nexus FT SM to meet these regulations you must select one of the following classified and approved
cord types:
EN – H 05 W5 - F HMR
UL – AWM Style 2587
CSA– AWM 1 A/B 11 A/B
For outdoor use, the power cord should meet at least IP65 encapsulation requirements. Do not turn the main
power on until you are ready to commission the WRH.
Fiber Optic and RF Connections
Fiber optic and RF cable connections should be verified both internally and externally before powering up the
equipment. This section illustrates the general internal connections of the Nexus FT SM. Verify these
connections with the as-built drawings and documents for your specific system configuration. Table 3-1 lists
the steps to add the external connections to the Nexus FT SM.
Table 3-1 Cable Connection Procedure
WARNING: For Nexus FT SMs supplied from the main power source, the main outlet must be
grounded.
Step Action
1
2
3
4