User's Manual

044-05320 Rev A 3-1
Chapter 3
Installation
Introduction
This chapter contains unpacking, inspection and installation instructions for installing and powering up the
Nexus FT SM.
Site Survey
Powerwave recommends that a site survey be performed prior to equipment ordering or installation.
Performing a detailed site survey reduces or eliminates installation and turn-up delays. Pay particular
attention to power plant capacity, cooling needs, floor space, and RF/DC cabling/breaker requirements.
Cabinet dimensions and weights are listed in Chapter 5.
Unpacking and Inspection
This equipment has been operated, tested, and calibrated at the factory. Carefully open containers to remove
equipment. Retain all packing material that can be reassembled in the event unit must be returned to the
factory. Perform the following steps:
Visually inspect equipment for damage that may have occurred during shipment. If possible, in the
presence of the delivery person.
Check for evidence of water damage, bent or warped chassis, loose screws or nuts, or extraneous
packing material in connectors.
If equipment is damaged, file a claim with the carrier once the extent of any damage is assessed.
If equipment must be returned to factory, please contact factory for a Return Material Authorization (RMA),
see Chapter 4.
Nexus FT SM Location
The Nexus FT SM is designed with a weather proof outdoor cabinet that can be mounted without any kind of
shelter from rain, snow or hail. The same unit can be installed indoors. A preferable site for the Nexus FT SM
is a location free of obstructions, easily accessible and allows for proper air-flow and ventilation.
If a Nexus FT SM is installed outdoors and can be exposed to direct sunshine, it is essential that air circulates
around the Nexus FT SM with no obstacles. The operating temperature must not exceed 131°F (55°C). A
shelter can be used to shade the Nexus FT SM from direct sunshine..
Mounting
The Nexus FT SM is designed for mounting on a cable using the hangar clips attached to the top of the unit.
Figure 3-1 Cable Mounting
DRAFT