User's Manual
Software and Hardware Compatibility Nexus FT Strand Mount
2-2 044-05320 Rev A
Software and Hardware Compatibility
There are different versions of CU PCBA software which can be combined with PCBAs of various revisions.
These have unique part numbers and revision information. Table 2-8 lists the software currently available in
combination with CU PCBA revisions.
Table 2-2 Hardware / Software Compatibility
This information is accurate as of 06/31/2007. As new versions of hardware and software are released without
prior notice, contact your Powerwave sales representative for information on the latest revision.
For detailed information, refer to the release notes for the CU software to be downloaded (normally found in
the readme.txt file provided with the program files).
Table 2-1 FON Connectors
Port Description
P101 SMA, electrical RF input port (to the optical TX port)
P102 SMA, electrical RF output port (from the optical RX port)
P103 SMA, electrical RF output port (15dB below the P102 port)
RX DIN/APC, optical input port (to the P102 and P103 RF ports)
TX DIN/APC, optical output port (from the P101 RF port)
P104 Used only for development and debugging
P105 4-pin male, door LED indicators. Used for the yellow and red LED indicators located
on the front cabinet door
P106 9-pin D-sub female, RS-232 used for local PC communication
P108/116 6-pin male, parallel connected power ports for the FON
P109 7-pin male, used for external alarm sensors
P110 W-link jumper, used to terminate units in a W-link. It has to be set in the parking
state for all units except for the first and last units in a W-link. The Parking state (P)
has the jumper between the center and bottom pins. The opposite state, with the
jumper between the tip and center pins, terminates(T) the W-link
P111/112 5-pin male, WLI ports used for interconnecting nodes in WLI-nets (IP or R2R
networks). They are identical and connected in parallel. One of the connectors is
intended to be used from the previous node and the other connector to the next
node in the network. Either can be used for the first and the last unit in the net chain
P113 2-pin male, used for the on-PCBA backup batteries
P114 Backup power output jumper, sets the backup power output state. The OFF state
has jumper between the center and left pins. This jumper has to be in the OFF state
when used in an OCM. Otherwise, it shall be in the ON state
P115 3-pin male, intended for future use
P117 SMA, electrical RF output port (15dB below the P101 port)
P130 34-pin, 2-line male, RCU port used for connecting an RCU. The connector contains
both the modem connection and RCU power supply
CU PCBA part number CU Software part number
500-13817-001 (previously K103/3) D631-18072-001
D631-18072-003
DRAFT