User's Manual

044-05207 Rev A 3-1
Chapter 3
Installation
Introduction
This chapter contains unpacking, inspection, and installation instructions for installing and powering up the
RMR.
Site Survey
Powerwave recommends that a site survey be performed prior to equipment ordering or installation.
Performing a detailed site survey reduces or eliminates installation and turn-up delays. Pay particular
attention to power plant capacity, cooling needs, floor space, and RF/DC cabling/breaker requirements.
Cabinet dimensions and weights are listed in Chapter 5.
Unpacking and Inspection
This equipment has been operated, tested, and calibrated at the factory. Carefully open container to remove
equipment. Retain all packing material that can be reassembled in the event unit must be returned to the
factory. Perform the following steps:
Visually inspect equipment for damage that may have occurred during shipment. If possible, in the
presence of the delivery person.
Check for evidence of water damage, bent or warped chassis, loose screws or nuts, or extraneous
packing material in connectors.
If equipment is damaged, file a claim with the carrier once the extent of any damage is assessed.
If equipment must be returned to factory, please contact factory for a Return Material Authorization (RMA),
see Chapter 4.
RMR Rack Location
The RMR is designed for use in an indoor, temperature controlled environment mounted on a 19 inch rack as
supplied by the customer. A preferable site for the RMR is a location free of obstructions, easily accessible
and allows for proper air-flow and ventilation.
Connections
This section describes general examples of how to connect the input and output ports on the RMR.
Main Power and Grounding
Local regulations need to be followed for the main power connection. RMRs are approved in accordance with
EN and UL/cUL regulations. This is, however, only valid if a classified power cord is used. For the Nexus FTto
meet these regulations you must select one of the following classified and approved cord types:
EN – H 05 W5 - F HMR
UL – AWM Style 2587
CSA– AWM 1 A/B 11 A/B
WARNING: For RMRs supplied from the main power source, the main outlet must be
grounded.