RF Connections
RF cable connections should be verified both internally and externally before powering up the equipment.
This section illustrates the general internal connections of the RMR. Verify these connections with the as-built
drawings and documents for your specific system configuration. Table 3-1 and Figure 3-2 show the steps to
connect the RMR to the Optical and RF Distribution(ORD) module.
Table 3-1 RMR Cable Connection Procedure
Figure 3-1 RMR to ORD cable connections
Step Action
1 Connect an RF cable between RMR Donor 1 IN terminal and A1 terminal on ORD RFM 1. Then
connect an RF cable between A terminal of RFM 1 to bottom terminal of FMR 1.
2 Connect an RF cable between RMR Donor 2 IN terminal and B1 terminal on ORD RFM 1. Then
connect an RF cable between B terminal of ORD RFM 1 to top terminal of ORD FMR 2.
3 Connect an RF cable between RMR Donor 1 OUT terminal and A1 terminal on ORD RFM 2. Then
connect an RF cable between A terminal of ORD RFM 2 to top terminal of ORD FMR 1.
4 Connect an RF cable between RMR Donor 2OUT terminal and B1 terminal on ORD RFM 2. Then
connect an RF cable between B terminal of RFM 2 to bottom terminal of FMR 2.