User's Manual Part 2
Initial Start-Up and Power Setting Procedures PAF-0813-E0-001
3-6 044-05287 Rev A
Figure 3-5 MCPA Front Panel Features
Initial Start-Up and Power Setting Procedures
The following paragraphs provide initial startup, and power setting procedures.
Initial Start Up
To complete initial startup, perform the instructions listed in Table 3-8.
Table 3-5 MCPA Installation Procedure
Step Action
1. Inspect MCPA 21-pin connector. Verify all pins are straight, no pins are recessed, and
alignment shield is not bent
2. Set MCPA power OFF/ON/RESET switch to OFF
3. Rotate MCPA quarter-turn fasteners counter-clockwise to unlock position shown in
Figure 3-8
4. Install MCPA(s) into subrack. To secure each MCPA, rotate quarter-turn fasteners
clockwise to lock position as shown in Figure 3-8
CAUTION: Excessive input power may damage MCPA. Before applying power, ensure MCPA
inputs and outputs are properly terminated at 50 ohms. Do not operate MCPA without a load
attached. Refer to Chapter 5 for input power requirements.
Table 3-6 Initial Startup Procedure
Step Action
1. Verify all input and output cables are properly connected
2. Turn on +27 VDC supply to MCPA
3. Set all MCPA front panel OFF/ON/RESET switches to ON (middle) position
4. Allow MCPAs to warm up for at least two minutes before taking power readings
Unlocked
Locked
LED Status
Indicator
RF Switch:
RESET
ON
OFF
Quarter-Turn
Fasteners
ON
OFF
ON
OFF
Alcatel Lucent