User's Manual Part 2

Introduction PAF-0813-E0-001
5-2 044-05287 Rev A
Torques (Inch-Pounds):
Metal Machine Screws
8-32
10-32
1/4-20
5/16-18
Coaxial Connectors
SMA
Type N
Type 7/16 DIN
20 to 24
32 to 40
70 to 80
140 to 160
5 to 6
12 to 15
220 to 230
Environmental Specifications/Features
Operating Temperature Range -5 - +45
o
C
Operating Humidity Range 5 -100% RH @ +40
o
C, Non-Condensing
Altitude -60 to 4000 meters
Seismic GR-63-CORE, Section 4.4.1, Zone 4
Lightning Surge Protection 3 kA @ 10/350 us waveform
5 kA @ 8/20 us waveform
Office Vibration GR-63-Section 5.4.2
Transportation Bump IEC 60068-2-29, Eb, 100 bumps per axis
Transportation Shock IEC 60068-2-27, Ea, three 15 g, 11 ms, half-sine shocks, Z
axis
Figure 5-1 System Specifications (Continued)