User's Manual
Table Of Contents
- High Power
- Wideband Radio Head (WRH-V)
- Table of Contents
- Chapter 1 - Product Description
- Chapter 2 - Controls, Indicators and Connectors
- Chapter 3 - Installation
- Chapter 4 - Maintenance
- Chapter 5 - Specifications
- Appendix A - Block Diagrams
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Overview
- Figure 1-1 Powerwave Wideband Radio Head (WRH)
- Chassis Design
- Wideband Amplifier PCBA (WBA)
- Multi-Carrier Power Amplifier PCBA (MCPA)
- Distribution PCBA (DIA)
- Figure 1-2 DIA PCBA
- Control Unit PCBA (CU)
- Figure 1-3 CU PCBA
- Low Noise Amplifier (LNA)
- Figure 1-4 LNA
- Duplex Filter (DPX)
- Fiber Optic Unit (FOU)
- Figure 1-5 FOU in WRH-V
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Figure 1-6 WRH-V Sub Unit Locations
- Figure 1-7 Fiber Optic Star Configuration
- Figure 1-8 Multi-operator System
- Chapter 2 Controls, Indicators and Connectors
- Chapter 3 Installation
- Chapter 4 Maintenance
- Chapter 5 Specifications
- Appendix A Block Diagrams
Introduction High Power Wideband Radio Head (WRH-V)
5-2 044-05251 Rev A
Downlink, Spurious and Emissions level -13 dBm/1 MHz (FCC)
-36 dBm (below 1 GHz, per ETSI EN 300 609-4)
-30 dBm (above 1 GHz, per ETSI EN 300 609-4)
Downlink power +43 dBm RMS (20 Watts) (for FCC - UMTS)
+40 dBm RMS (10 Watts) (for ETSI - GMS/EDGE)
Noise figure excluding fiber optic link 4 dB
Fiber-Optic Link Budget 10 dBo
Receiver input port return loss 14 dB
Power supply voltage 115/230 VAC
21-60 VDC
Maximum Current Draw (Single Band) 6 A @ 115 VAC
3 A @ 230 VAC
15A @ 21-60 VDC
Maximum Current Draw (Dual Band) 6 A @ 115 VAC
3 A @ 230 VAC
15A @ 21-60 VDC
Recommended Fuse size
Single Band
Dual Band
10 A for AC voltage
20 A for DC voltage
20 A for AC voltage
40 A for DC voltage
Power consumption 210 W typical, 300 W max (Single band)
420 W typical, 600 W max (Dual band)
Impedance
Input
Output
Not Applicable - Optical input
50 Ω
Mechanical
Dimensions (W x H x D in inches) 465 x 530 x 195 mm (18.3 x 20.9 x 8.3 in) incl. hinges (low cover)
465 x 530 x 310 mm (18.3 x 20.9 x 12.3 in) incl hinges (high cover)
Weight <25 kg (55 lbs) low cover
<44 kg (96 lbs) high cover
Service Antenna port connector 7/16 DIN Female
Donor Optical port connector FC/APC
Environmental
Operating Temperature Range -25 °C to +55 °C (-13°F to +131°F)
Altitude -142 m to 4000 m (-466 ft. to 13100 ft.
Casing class NEMA4/IP65
Fiber Optic Node (FON)
Bandwidth @ 3dB 800 – 2200 MHz
Power Consumption, total <5 W
Table 5-1 WRH-V Specifications (Continued)