User's Manual

Table Of Contents
High Power Wideband Radio Head (WRH-V) Field Replaceable Units
044-05251 Rev A 4-7
WRH-V
To replace a WRH-V, follow the steps listed in the Table 4-5.
Table 4-4 PSU Replacement Procedure
Step Action
1 Loosen all four locking screws on front of cabinet
2 Open WRH-V door and secure
3 Disconnect main power plug from PSU(Location 1 shown in Figure 4-1)
4 Disconnect power cable bundle from PSU(Location 2 shown in Figure 4-1)
5 Loosen but do not remove screws securing PSU using a 5mm Allen key and remove PSU (Location 3
shown in Figure 4-1)
6 On new AC power supply, if used, set input voltage switch on PSU to correct input voltage -- 115 VAC
or 230 VAC (Location 4 shown in Figure 4-1)
7 On new DC power supply, if used, verify that the supply voltage is 24 VDC or 48 VDC as stated on
label on PSU (Location 5 shown in Figure 4-1)
8 Set new PSU to correct output supply voltage (27 VDC) by moving wire connection plug as illustrated
on label on PSU (Location 6 shown in Figure 4-1)
9 Mount new PSU with all four fixing screws (Location 3 shown in Figure 4-1)
10 Connect PSU to DIA PCBA (Location 2 shown in Figure 3-9) with cable marked VE007 98/1. This
cable must be used in all situations. If only one connection is available on DIA PCBA, the second
connector may be tied out of the way with a cable tie
11 Insert power cord (AC power supply) or connect DC power cable brown wire to positive (+) pole and
blue wire to negative (-) pole (DC power supply)
12 Close WRH-V door and secure with four locking screws on front of cabinet
WARNING: A fully loaded WRH-V can weigh 96lbs. Lifting of the WRH-V should be done
by two people. Do not attempt to carry the WRH-V up a ladder.