User's Manual
Table Of Contents
- High Power
- Wideband Radio Head (WRH-V)
- Table of Contents
- Chapter 1 - Product Description
- Chapter 2 - Controls, Indicators and Connectors
- Chapter 3 - Installation
- Chapter 4 - Maintenance
- Chapter 5 - Specifications
- Appendix A - Block Diagrams
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Overview
- Figure 1-1 Powerwave Wideband Radio Head (WRH)
- Chassis Design
- Wideband Amplifier PCBA (WBA)
- Multi-Carrier Power Amplifier PCBA (MCPA)
- Distribution PCBA (DIA)
- Figure 1-2 DIA PCBA
- Control Unit PCBA (CU)
- Figure 1-3 CU PCBA
- Low Noise Amplifier (LNA)
- Figure 1-4 LNA
- Duplex Filter (DPX)
- Fiber Optic Unit (FOU)
- Figure 1-5 FOU in WRH-V
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Figure 1-6 WRH-V Sub Unit Locations
- Figure 1-7 Fiber Optic Star Configuration
- Figure 1-8 Multi-operator System
- Chapter 2 Controls, Indicators and Connectors
- Chapter 3 Installation
- Chapter 4 Maintenance
- Chapter 5 Specifications
- Appendix A Block Diagrams
High Power Wideband Radio Head (WRH-V) Field Replaceable Units
044-05251 Rev A 4-7
WRH-V
To replace a WRH-V, follow the steps listed in the Table 4-5.
Table 4-4 PSU Replacement Procedure
Step Action
1 Loosen all four locking screws on front of cabinet
2 Open WRH-V door and secure
3 Disconnect main power plug from PSU(Location 1 shown in Figure 4-1)
4 Disconnect power cable bundle from PSU(Location 2 shown in Figure 4-1)
5 Loosen but do not remove screws securing PSU using a 5mm Allen key and remove PSU (Location 3
shown in Figure 4-1)
6 On new AC power supply, if used, set input voltage switch on PSU to correct input voltage -- 115 VAC
or 230 VAC (Location 4 shown in Figure 4-1)
7 On new DC power supply, if used, verify that the supply voltage is 24 VDC or 48 VDC as stated on
label on PSU (Location 5 shown in Figure 4-1)
8 Set new PSU to correct output supply voltage (27 VDC) by moving wire connection plug as illustrated
on label on PSU (Location 6 shown in Figure 4-1)
9 Mount new PSU with all four fixing screws (Location 3 shown in Figure 4-1)
10 Connect PSU to DIA PCBA (Location 2 shown in Figure 3-9) with cable marked VE007 98/1. This
cable must be used in all situations. If only one connection is available on DIA PCBA, the second
connector may be tied out of the way with a cable tie
11 Insert power cord (AC power supply) or connect DC power cable brown wire to positive (+) pole and
blue wire to negative (-) pole (DC power supply)
12 Close WRH-V door and secure with four locking screws on front of cabinet
WARNING: A fully loaded WRH-V can weigh 96lbs. Lifting of the WRH-V should be done
by two people. Do not attempt to carry the WRH-V up a ladder.