User's Manual
Multi-Carrier Power Amplifier Specifications G3L-1929-160-001 MCPA
5-2 044-05305 Rev A
Controls Three position toggle switch: OFF/ON/RESET.
Alarm Indication LED; Green (normal), Yellow (minor alarm), Red (Major alarm).
Platform Compatibility G3L-1929-160-001 will reduce power level to G3L-1929-120 levels if
placed in a G3L-1929-120 subrack. PA will perform at rated power
levels with Software upgrade for subrack.
RF Input / Output / Status / Alarm /
Control / DC Input Connector
21-pin D-subminiature combo connector.
DImensions 354.6 mm high, 99 mm wide, 499.9 mm deep (including handles)
(13.96” H X 3.9” W X 19.7” D)
Weight 12.97 kg (28.5 lbs)
Environmental Specifications/Features
Operating Temperature Range -33 ºC. to +50 ºC.
Storage Temperature -40 ºC. to +70 ºC.
Operating Humidity, Normal 5% to 95% relative humidity (non-condensing).
Storage Humidity 5% to 95% relative humidity (non-condensing).
RF Power Derating for DC Input Voltage. 28.1 to 30.0 VDC - 0.5 dB
26.0 to 28.0 VDC - rated operation
25.0 to 25.9 VDC - 1.0 dB
24.0 to 24.9 VDC - 1.5 dB
21.0 to 23.9 VDC - 2.0 dB
Table 5-1. MCPA Specifications (Continued)