User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Human Exposure of RF Radiation
- Sub Unit Overview
- Wideband Amplifier PCBA (WBA)
- Power Amplifier PCBA (PA)
- Multi-Carrier Power Amplifier PCBA (MCPA)
- Booster Amplifier PCBA (BA)
- Control Unit PCBA (CU)
- Distribution PCBA (DIA)
- Low Noise Amplifier (LNA)
- Duplex Filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Sub Unit Locations
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Indicators and Connectors
- Chapter 3 Installation
- Chapter 4 Maintenance
- Chapter 5 Specifications
- Appendix A Block Diagrams
Wideband Radio Head Return For Service Procedures
044-05251 Rev A 4-7
WRH
To replace a WRH, proceed as desribed in the Table 4-5.
Table 4-5 WRH Replacement Procedure
Return For Service Procedures
When returning products to Powerwave, the following procedures will ensure optimum response.
Obtaining an RMA
A Return Material Authorization (RMA) number must be obtained prior to returning equipment to the
factory for service. Pease contact our Repair Department at 1-714-466-1000 to obtain this number, or
FAX your request to 1-714-466-5800. Failure to obtain this RMA number may result in delays in
receiving repair service.
Repackaging for Shipment
To ensure safe shipment of the unit, it is recommended that the original package designed for
shipping the unit be reused. If it is not available, contact Powerwave’s Customer Service Department
for packing materials.
Remote Control Unit (RCU)
The RCU provides remote control of Powerwave WRHs. It contains an integrated mobile phone,
modem and power supply backup. The RCU is installed in the bottom front of the cabinet, on top of
the PSU as illustrated in Figure 4-1.
The RCU is connected to P130 on either an RCI or FON. A jumper is required between pins 1 and 2
on the RCI if the P130 cable connector is disconnected. If a main power failure occurs, the unit has a
battery with enough capacity for sending a number of alarms.
Step Action
1 Open WRH door and secure
2 Disconnect main power plug from PSU
3 Verify all cables connected to WRH are labeled before disconnecting, then disconnect all cables
4 Remove mounting screws from bottom legs of WRH and loosen mounting screws in top legs
5 Close and secure door
WARNING: A fully loaded WRH can weigh 96lbs. Lifting of the WRH should be done by two
people. Do not attempt to carry the WRH up a ladder.
6 Lift the WRH off the mount hinges
7 Replace WRH in reverse order
8 Connect PC to OM Online port and verify configuration. For Fiber Optic installations, verify IP
address.