User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
Commissioning AR Standard Repeater
3-14 044-05250 Rev A
Measuring Output Signal Levels
Uplink and downlink output signal test ports are located on the DCs at the donor and service
antenna connectors, provided the unit is configured with optional DCs. These test ports are
labeled TEST -30dB as illustrated in Figure 3-16 and are intended for signal measuring using
a spectrum analyzer.
Figure 3-16 Output Signal Level Ports
The coupling is approximately -30dB. There is no directivity in these test ports; both uplink
and downlink signal can be measured.
Voltage Testpoints
Testpoints are available on the DIA in the cabinet from which the various internal supply
voltages can be measured using a standard multimeter. The testpoint positions and names
are identified in the DIA section of Chapter 2.
MS
DPX
ANT
TEST
DC
-30 dB
-20 dB
MS
DPX
ANT
TEST
DC
-30 dB
-20 dB
POWER SUPPLY UNIT
ALLGO N INNOVATIO N
SWEDEN M105 R6
1
PARKING
FOR W5
W5
8
P27
W6B 10
1
P33
ALARM
P23
LNA
UP-LINK
P32
MODEM
A
U
X
1
P28
DOOR
5
9
6
1
1
16
1
1
M
-
>
S
P11
P34
8
9
15
P26
15 16
S
-
>
M
1
2
3
89
P
3
6
5
X0A
X0B
2
V2
1
16
P12 P13
1
1
1
16
16
16
P4
P5
P6
c
b
a
c
b
a
c
b
a
c
b
a
1P232
1
b
a
1
16P3
16
1
16
P14
1
V1
1
1
1
1
1
4
6
1
15
6
9
15
2
16
1
2
4
5
8
5
P35
P21
PSU
6
10
P31
PC
P29
P24
P25
GND
7
6V6
LNA
DOWN-LINK
LED
P22
1
2
DC
TEST
–30 dB
DC
TEST
–30 dB