User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
AR Standard Repeater Optional Connections
044-05250 Rev A 3-11
Main Power Breakdown Relay
To be able to distinguish PSU faults from power failure, a main power breakdown relay can be
used. This relay is not included in the AR repeater and has to be mounted outside the
repeater cabinet. The relay intended for this purpose must fulfil the following specifications:
Closing time: Max. 30 milliseconds
Insulation coil/contact: Min. 4KV
A main power connected relay must also be in compliance with valid local regulations. Figure
3-13 illustrates the connection points and Table 3-5 lists the steps for making the connections.
Table 3-5 Main Power Breakdown Relay Connection
Figure 3-13 Main Power Breakdown Relay Connection
Step Action
1 Connect a currentless closed relay contact to pin AI1 and AIC on the P33 alarm connec-
tor. An alarm is initiated by short-circuiting the pins. For the BMU the main power break-
down cables are connected to pin AI1 and AIC in the P109 port on the FON.
2 Connect the relay coil. It must be supplied from the same fuse as the repeater.
3 After commissioning, select Mains Breakdown in the alarm configuration window in OM-
Online or OMS. Refer to the OM-Online User Manual.
MS
DPX
ANT
TEST
DC
-30 dB
-20 dB
POWER SUPPLY UNIT
ALLGON INNOVATION
SWEDEN M105 R6
1
PARKI NG
FOR W5
W5
8
P27
W6B 10
1
P33
ALARM
P23
LNA
UP-LINK
P32
MODEM
A
U
X
1
P28
DOOR
5
9
6
1
1
16
1
1
M
-
>
S
P11
P34
8
9
15
P26
15 16
S
-
>
M
1
2
3
89
P
3
6
5
X0A
X0B
2
V2
1
16
P12 P13
1
1
1
16
16
16
P4
P5
P6
c
b
a
c
b
a
c
b
a
c
b
a
1P232
1
b
a
1
16P3
16
1
16
P14
1
V1
1
1
1
1
1
4
6
1
15
6
9
15
2
16
1
2
4
5
8
5
P35
P21
PSU
6
10
P31
PC
P29
P24
P25
GND
7
6V6
LNA
DOWN- LI NK
LED
P22
1
2
P33:AICP33:AI1
P33