User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
AR Standard Repeater PCBA Connections
2-14 044-05250 Rev A
Software and Hardware Compatibility
There are different versions of repeater CU software which can be combined with PCBAs of
various revisions. These have unique part numbers and revision information. Below, you will
find a table of repeater software currently available in combination with CU PCBA revisions.
Table 2-14 Hardware / Software Compatibility
This information is accurate as of 1/31/2007. As new versions of hardware and software are
released without prior noticing, contact your Powerwave sales representative if in doubt about
the latest revision status.
For detailed information, refer to the release notes for the CU software to be downloaded
(normally found in the readme.txt file provided with the program files).
CU PCBA
part #
CU Software
part #
Comments
K103/1
or
K103/2
SA102 01/2 For GSM channel selective = 4 channels, band selective
800-900MHz fixed bandwidth only, and combined repeater
(800/900MHz). No traffic statistics.
K103/2 SA102 02/1 For GSM, DCS, PCS channel selective = 8 channels, band
selective 800 – 900MHz fixed or adjustable bandwidth,
band selective 1800MHz or 1900MHz and combined
repeater. Supports R2R link.
Supports stacked channels.
K103/2 SA102 02/2 For 800/1900MHz CDMA = 4 channels.
SA102 02/4 For 800/1900MHz channel selective operation.
SA102 02/5 For 800/1900MHz band selective operation.
K103/3 SA102 06/x
SA102 07/x
SA102 08/x
More memory. MAC ID is added on the PCBA. R2R func-
tionality integrated.