User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
AR Standard Repeater PCBA Connections
2-12 044-05250 Rev A
PSU
The PSU is located in the bottom middle of the cabinet or in an equipped high cover as
illustrated in Figure 2-8. The PSU has all the voltages required for all repater types. It has
capacity for one repeater, including the radio circuitry, fiber optics, modem, etc. In some high
power repeater types, the PSU also supplies the BA. Multi-band high power repeaters always
require a second PSU. There are two PSU types with different input voltages:
1. 115/230V 50/60Hz, 300W input max.
2. 21- 60V DC, 300W input max.
The DIA provides most of the internal connection between the repeater units and to external
ports. Connectors involved in the installation are also located on the DIA. Table 2-13
describes these connections.
Figure 2-8 Power Supply Unit (PSU)
Table 2-13 PSU Connectors
Port Description
P27 Auxiliary Port (8-pin male) - Used to power the old RCU. It is located on the DIA
to the left in the cabinet. Pins 2 and 3 must always be interconnected to provide
the CU and ALI/RCI PCBs with voltage supply. If there is no cable connected,
pins 2 and 3 must be interconnected with a jumper.
P31 RS-232 PC Port (9-pin D-sub female) - Used for local PC communication. It is
located on the DIA to the right in the cabinet.
P32 RS-232 Modem port (9-pin D-sub male) - V.24 interface used for the old RCU.
It is located on the DIA to the left in the cabinet.
MS
DPX
ANT
TEST
DC
-30 dB
-20 dB
MS
DPX
ANT
TEST
DC
-30 dB
-20 dB
POWER SUPPLY UNIT
AL LGON INNOVATI ON
SWEDEN M105 R6
1
PARKI NG
FOR W5
W5
8
P27
W6B 10
1
P33
ALARM
P23
LNA
UP-LINK
P32
MODEM
A
U
X
1
P28
DOOR
5
9
6
1
1
16
1
1
M
-
>
S
P11
P34
8
9
15
P26
15 16
S
-
>
M
1
2
3
89
P
3
6
5
X0A
X0B
2
V2
1
16
P12 P13
1
1
1
16
16
16
P4
P5
P6
c
b
a
c
b
a
c
b
a
c
b
a
1P232
1
b
a
1
16P3
16
1
16
P14
1
V1
1
1
1
1
1
4
6
1
15
6
9
15
2
16
1
2
4
5
8
5
P35
P21
PSU
6
10
P31
PC
P29
P24
P25
GND
7
6V6
LNA
DOWN- LINK
LED
P22
1
2
P33
P27
P3
1
P32
P34
P28
P36