User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
PCBA Connections AR Standard Repeater
044-05250 Rev A 2-9
FOU
FOU connections depend on the repeater type and if the FOU is connected to the donor or
service side. The RF connections for the FOU and the DPX used on the RF side are
illustrated in Figure 2-6 and listed in Table 2-10.
Figure 2-6 FOU
Table 2-10 FOU/DPX connections
on the donor side (BMU or RMU)
Port Connected to
ANT BMU: BS -20dB on the donor (BS) DC
RMU: DPX on the donor (BS) DC
HI BMU: P101 on the FON (or a CMB or CMD)
RMU: IN on the LNA/DL
LO BMU: P102 on the FON (or a CMB or CMD)
RMU: P5 on the PA/UL
on the service side (FOR and WRH)
Port Connected to
ANT Service antenna
HI FOR: P5 on the PA/DL
WRH: P5 on the PA/DL or P4 on the BA
LO FOR: IN on the LNA/UL
WRH: IN on the LNA/UL or P2 101 on the WBA
P102
P130
Beryllium
oxide
hazard
P103
P101
P114
P108P116P111
P105P109P115
P106
P104
RX
TX
P113
P112
P110
FON
DPX
ANTLO HI
P102
P101
FOU