User's Manual

Table Of Contents
AR Standard Repeater PCBA Connections
2-4 044-05250 Rev A
BSA PCBA
Table 2-4 lists the connectors and connections for the BSA PCABA. Coaxial connector P101
is the input port and coaxial connector P301 is the output port. The signal from this port is fed
to the PA input port P4. The PA output port P5 is connected to the duplex filter of the same
path direction.
Table 2-4 BSA PCBA Connections
PA PCBA
Coaxial connector P4 is the input port and coaxial connector P5 is the output port. PA output
port P5 is connected to the DPX of the same path direction.
BA PCBA
Table 2-5 lists the connectors and connections for the BA PCABA. Coaxial connector P3 is
the input port (fed by the DL PA) and coaxial connector P4 is the output port. The signal from
this output is fed, via the DL DPX and DC, to the DL antenna.
Table 2-5 BA PCBA Connections
Port Connected to
BSA/DL (position 1 from left)
P101 OUT1 on the LNA/DL low noise amplifier
P301 P4 on the PA/DL PCBA
PA/DL (position 2 from left)
P4 P301 on the BSA/DL PCBA
P5 HI on the service DPX duplex filter
BSA/UL (position 3 from left)
P101 OUT1 on the LNA/UL low noise amplifier
P301 P4 on the PA/UL PCBA
PA/UL (position 4 from left)
P4 P301 on the BSA/UL PCBA
P5 LO on the donor DPX duplex filter
WARNING: The PA PCBA has power transistors which may contain beryllium oxide
(BeO) that is poisinous. Refer to the Safety section located in Chapter 1.
Port Connected to
P3 P5 on the PA/DL PCBA
P4 HI on the service DPX