User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
Introduction AR Standard Repeater
5-2 044-05250 Rev A
AR1700 Family - GSM 900 Channel Selective
Frequency band UL 890-915 MHz
Frequency band DL 935-960 MHz
Number of channels 1 to 8
Absolute group delay 5 µs
Filter bandwidth (remotely adjustable) 200 KHz
Gain adjustment range (in 1 dB steps) 55-90dB
Gain (max variation –25 to +55 °C) 4dB
Pass band ripple 3dB
Maximum input power (non-destructive) +13dBm
Output power RMS, one carrier, DL +33dBm
Noise figure at 85 dB gain, 25° C (typical) 4dB
AR2100/2700 Family - GSM 1800 Channel Selective
Frequency band UL 1710-1785 MHz
Frequency band DL 1805-1880 MHz
Number of channels 1 to 8
Absolute group delay 5 µs
Filter bandwidth (remotely adjustable) 200 KHz
Gain adjustment range (in 1 dB steps) 55-90dB
Gain (max variation –25 to +55 °C) 4dB
Pass band ripple 3dB
Maximum input power (non-destructive) +13dBm
Output power RMS, one carrier, DL +32dBm
Noise figure at 85 dB gain, 25° C (typical) 4dB
AR2200 Family - GSM 1800 Band Selective
Frequency band UL 1710-1785 MHz
Frequency band DL 180-1880 MHz
Number of channels N/A
Absolute group delay 6 µs
Filter bandwidth (remotely adjustable) 0.5-16.9 MHz, remotely adjustable
Gain adjustment range (in 1 dB steps) 45-85dB