User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Overview
- Repeaters with RF / RF Transmission
- Repeaters with RF / Fiber Optic Transmission
- Repeater with Fiber Optics / RF Transmission
- Combined Repeater
- Repeater Chassis Design
- Channel Amplifier PCBA for GSM and EDGE (CHE)
- CDMA/WCDMA Segment Amplifier PCBA (CSA)
- Band Selective Amplifier PCBA (BSA)
- Power Amplifier PCBA (PA)
- Booster Amplifier (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Directional Coupler (DC)
- Low Noise Amplifier (LNA)
- Duplex filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Combiner unit (CMB)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Repeater-to-Repeater Interface Adapter (RIA)
- CSel GSM Repeater
- CSel CDMA/WCDMA Repeater
- CSel High Power CDMA/WCDMA Repeater
- BSel Repeater
- BMU
- RMU
- FOR
- Combined Repeater
- Shaded Area
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Connections and Indicators
- Chapter 3 Installation
- Introduction
- Site Survey
- Unpacking and Inspection
- Repeater Location
- Mounting
- Connections
- Main Power and Grounding
- RF-to-RF Repeater Connections
- Table 3-1 RF-to-RF Connections Procedure
- Table 3-2 BMU RF-to-Fiber Connections Procedure
- Table 3-3 RMU RF-to-Fiber Connections Procedure
- Table 3-4 FOR RF-to-Fiber Connections Procedure
- Table 3-5 Main Power Breakdown Relay Connection
- Table 3-6 PSU Replacement Procedure
- Table 3-7 Initial Statup Procedure
- Chapter 4 Maintenance
- Introduction
- Periodic Maintenance
- Table 4-1 Recommended Periodic Maintenance
- Table 4-2 Alarm Troubleshooting
- Table 4-3 FON Replacement Procedure
- Table 4-4 PSU Replacement Procedure
- Table 4-5 Repeater Replacement Procedure
- Return For Service Procedures
- Obtaining an RMA
- Repackaging for Shipment
- Remote Control Unit (RCU)
- RCU for Radio Communication
- RCU for Telephone Line Communication
- Previous RCU Version for GSM 900/1800/1900
- Repeater-to-Repeater Link (R2R)
- Traffic Statistics
- Battery Backup (BBU)
- 7/16" Antenna Cable Connectors
- Operation and Maintenance System (OMS)
- Chapter 5 Specifications
- Appendix A Block Diagrams
PCBA Connections AR Standard Repeater
044-05250 Rev A 2-3
CSA PCBA
Table 2-3 lists the connectors and connections for the CSA PCABA. Coaxial connector P101
is the input port and coaxial connector P301 is the output port. The signal from this port is fed
to the PA input port P4. The PA output port P5 is connected to the duplex filter of the same
path direction.
Table 2-3 CSA PCBA Connections
P701 Input on the CMB/DL combiner
CHE3/UL (position 3 from left)
P101 OUT1 on the LNA/UL low noise amplifier
P701 4 channels: Input on the CMB/UL combiner
2 channels: LO on the service DPX duplex filter
CHE4/UL (position 4 from left)
P101 OUT2 on the LNA/UL low noise amplifier
P701 Input on the CMB/UL combiner
WARNING: The CHE PCBA has power transistors which may contain beryllium oxide
(BeO) that is poisinous. Refer to the Safety section located in Chapter 1.
Port Connected to
CSA/DL (position 1 from left)
P101 OUT1 on the LNA/DL low noise amplifier
P301 P4 on the PA/DL PCBA
PA/DL (position 2 from left)
P4 P301 on the CSA/DL PCBA
P5 For the channel selective high power CDMA/WCDMA repeater: P3 on the BA/
DL PCBA
For all other models: HI on the service DPX duplex filter
CSA/UL (position 3 from left)
P101 OUT1 on the LNA/UL low noise amplifier
P301 P4 on the PA/UL PCBA
PA/UL (position 4 from left)
P4 P301 on the CSA/UL PCBA
P5 LO on the donor DPX duplex filter