PCBA Indicators Wideband Radio Head
2-2 044-05251 Rev A
PCBA Indicators
This following paragraphs describe the LED indicators on the main PCBAs inside the WRH.
CU PCBA
Figure 2-3 illustrates the location of the LEDs on the CU and Table 2-1 describes their indications.
Figure 2-3 CU PCBA Indicators
Table 2-1 CU PCBA LED Indicators
FON PCBA
The FON is illustrated in Figure 2-4 and the LED indicators are described in Table 2-2.
LED Description
WLI Wire Line Interface. A flashing green LED indicates the unit is receiving data over the
subcarrier. A steady green LED indicates: the unit is currently not receiving any data,
is currently not a control station or there is no other node in the network.
DATA Blue LED indicating data transmission in the W-net.
POWER Yellow LED indicating present power and remains steady after power is switched on.
BOOT Steady red LED when the CU boots (10 – 15 seconds after main power is switched
on), then flashing red (5 – 10 seconds), then off if no error is detected. If an error is
detected LED will stay on.
FAULT Flashing red LED for 15 – 20 seconds after main power is switched on. Flashes for
less serious alarms (Error) and is on solid for fatal alarms (Critical).
OPER Steady green LED indicates WRH is ready for operation.
WARNING: A lithium battery is permanently mounted on the CU PCBA. Due to risk of
explosion, this battery must not be removed. In case of battery malfunction, replace the
CU PCB.