User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Sub Unit Overview
- Wideband Amplifier PCBA (WBA)
- Power Amplifier PCBA (PA)
- Multi-Carrier Power Amplifier PCBA (MCPA)
- Booster Amplifier PCBA (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Low Noise Amplifier (LNA)
- Duplex Filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Sub Unit Locations
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Indicators and Connectors
- Chapter 3 Installation
- Chapter 4 Maintenance
- Chapter 5 Specifications
- Appendix A Block Diagrams

Wideband Radio Head Troubleshooting
044-05251 Rev A 4-5
Ceasing The cause of the alarm has ceased.
41 RF block-
ing
Chan-
nel #,
UL/DL
Error Constant carrier, PA off. Uplink carrier has been con-
stantly above 27dBm more than 10 seconds.
Ceasing The cause of the alarm has not been detected for 10
seconds.
42 Antenna
isolation
WBA #,
Chan-
nel #,
UL/DL
Warning Low antenna isolation. The antenna isolation is lower
than the gain set. Gain is reduced by 10dB – 13dB
below the oscillation point. Suggested remedy:
Decrease gain or increase antenna isolation.
Error Low antenna isolation at lowest gain. The gain has
been reduced as much as possible but the oscillation
still remains. The amplifier is turned off. Suggested
remedy: Decrease gain or increase antenna isolation.
Ceasing Normal operation again, that is no oscillation can be
detected 13dB above the gain set.
44 Low sta-
bility mar-
gin
Chan-
nel #,
UL/DL
Warning MRX has detected that antenna isolation is below the
gain set. The gain is reduced 10– 13dB below oscilla-
tion point. Suggested remedy: Decrease the gain or
increase the antenna isolation.
Ceasing The cause of the alarm has ceased.
48 Battery
backup
fault
External Error If a battery backup unit alarm is connected to external
alarm 2, then the operator can configure the WRH to
display this alarm when the battery backup unit indi-
cates alarm.
Ceasing The cause of the alarm has ceased.
50 Fiberopti-
cal error
FOT
fiber
optics
Config-
urable
If a fiber unit alarm is connected to external alarm 3,
then the operator can configure the WRH to display
this alarm when the fiber optical unit indicates alarm.
Ceasing The cause of the alarm has ceased.
55 R2R
Queue full
CU None R2R transmit queue is full, messages are lost. Sug-
gested remedy: Check configuration and cables.
56 R2R Node
lost
CU None An R2R node is lost. Suggested remedy: Check if
node is still connected and operating.
Warning An R2R node is lost. Suggested remedy: Check if
node is still connected and operating.
57 R2R HW
Error
RIA Error R2R HW failure because the CU cannot read the
MAC-ID of the RIA PCBA or any other HW error in
the R2R logic. Suggested remedy: Replace the RIA
PCBA.
BSC
R2R
Error R2R HW failure because the CU cannot read the
MAC-ID or any other HW error in the R2R logic. Sug-
gested remedy: Replace the WRH.
FON
R2R FO
Error R2R HW failure because the CU cannot read the
MAC-ID or any other HW error in the R2Rlogic. Sug-
gested remedy: Replace the FON PCBA.