User's Manual
Table Of Contents
- Revision Record
- Table of Contents
- List of Figures
- List of Tables
- Abbreviations
- Chapter 1 Product Description
- Introduction
- Scope of Manual
- Safety
- Warning Signs
- Human Exposure of RF Radiation
- Radiation Safety Distances
- Electrostatic Discharge (ESD)
- Sub Unit Overview
- Wideband Amplifier PCBA (WBA)
- Power Amplifier PCBA (PA)
- Multi-Carrier Power Amplifier PCBA (MCPA)
- Booster Amplifier PCBA (BA)
- Distribution PCBA (DIA)
- Control Unit PCBA (CU)
- Low Noise Amplifier (LNA)
- Duplex Filter (DPX)
- Fiber Optic Unit (FOU)
- Fiber Optic Node (FON)
- Power Supply Unit (PSU)
- Remote Control Unit (RCU)
- Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI)
- Sub Unit Locations
- Fiber Optic Distribution Networks
- Multi-Operator Configurations
- Chapter 2 Controls, Indicators and Connectors
- Chapter 3 Installation
- Chapter 4 Maintenance
- Chapter 5 Specifications
- Appendix A Block Diagrams

PCBA Indicators Wideband Radio Head
044-05251 Rev A 2-3
FON PCBA
The FON is illustrated in Figure 2-4 and the LED indicators are described in Table 2-2.
Figure 2-4 FON LED Indicators
Table 2-2 FON LED Indications
LED Description
FLI or
F2F
Green LED. Fiber Line Interface (FLI). Flashing LED indicates the unit is
receiving data over the sub carrier. A steady LED indicates the unit has
detected an FLI sub-carrier, but is not carrying any data.
OPER Green LED. Lights up for approximately 15 seconds after the mains is
switched on. When steady, it indicates the unit is ready for operation.
FAULT Red LED. Flashes for 15 – 20 seconds after the mains is switched on. Will
flash for less serious alarms and be steady for fatal alarms.
POWER Yellow LED. Indicates power is present
BOOT Red LED. Steady LED when the control unit boots up (10 – 15 seconds
after the mains is switched on). Next enters a flashing state for 5 – 10 sec-
onds. If no error is detected, the LED is off. If an error occurs, the LED
remains on.
WLI Green LED. Wire Line Interface. Flashing LED indicates unit is receiving
data over the subcarrier. A steady LED indicates one of the following: The
unit is not currently receiving any data, the unit is not currently a control
station or there is no other node in the network.
DATA Blue LED. Indicates data transmission in the W-net
BATT Green LED. Steady LED indicates battery pack is currently used as power
source
CHARGE Yellow LED. Steady LED indicates battery charging
P102
P130
Beryl lium
oxide
hazard
P103
P101
P114
P108P116P111
P105P109P115
P106
P104
RX
TX
P113
P112
P110
OPER
FAULT
POWER
BOOT
WLI/R2R
DATA
BATT
CHARGE
FLI