G3L-850-160 Multi-Carrier Power Amplifier Installation and Service Manual 044-05236 Rev A June 2006
© 2006 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies, and the Powerwave logo are registered trademarks. This Powerwave product is intended only for installation in a RESTRICTED ACCESS LOCATION and this Powerwave product is designed to operate within the normal operating (typical operating) ranges or conditions specified in this document. Operation of this equipment beyond the specified ranges in this document may cause: 1.
G3L-850-160 MCPA Warnings, Cautions, and Notes Warnings, Cautions, and Notes Warnings, Cautions, and Notes are found throughout this manual where applicable. The associated icons are used to quickly identify a potential condition that could result in the consequences described below if precautions are not taken. Notes clarify and provide additional information to assist the user. WARNING: This warning symbol means danger. You are in a situation that could cause bodily injury or death.
Revision Record G3L-850-160 MCPA Revision Record Revision Letter A ii Date of Change Reason for Change June 2006 Initial Release 044-05236 Rev A
Table of Contents Chapter 1 - Product Description 1.1.Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2.Scope of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.3.Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.4.
List of Figures G3L-850-160 MCPA List of Figures Figure 1-1 Figure 1-2 Figure 2-1 Figure 2-2 Figure 3-1 Figure 4-1 Figure 5-1 Figure 5-2 MCPA Front and Rear Isometric Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MCPA Functional Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MCPA Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1 Product Description 1.1 Introduction This manual contains information and procedures for the installation, operation, and maintenance of the G3L-850-160 Multi-Carrier Power Amplifier (MCPA). 1.2 Scope of Manual This manual is intended for use by service technicians familiar with similar types of equipment. It contains service information required for the equipment described and is current as of the printing date.
Functional Description • G3L-850-160 MCPA Controller Rear Front Figure 1-1 MCPA Front and Rear Views 1-2 044-05236 Rev A
G3L-850-160 MCPA Functional Description FIRST LOOP SECOND LOOP Pilot Tone First Loop Phase and Gain Premain Amplifier Delay Filter Main Amplifier RF Out RF Sample Pilot Tone Generator RF In Preamp Error Out Second Loop Phase and Gain Delay First Loop Detection First Loop Control Second Loop Control Forward Power / Pilot Tone Detect Reflected Power (VSWR) Controller -5 +15 +9 +5 VDC VDC VDC VDC +27 VDC Error Amplifier System Faults Front Panel Status User Interface LED Control ON/OFF
Cooling G3L-850-160 MCPA 1.4.3 Feed-forward Loop Control Circuits The primary function of the first loop is to amplify the carrier signals and isolate an error signal for the second loop. It does this by amplifying the carrier signals and isolating an error signal which is passed to the second loop. The first loop control section phase shifts the main input signals by 180 degrees and constantly monitors the output for correct phase and gain.
G3L-850-160 MCPA 1.6 Power Distribution Power Distribution The host system provides +27 VDC power for the MCPA. The DC/DC converter and voltage regulator in the MCPA converts the +27 VDC to +15 VDC, +9 VDC, +5 VDC, and -5 VDC for internal use. The MCPA has no built-in short-circuit protection. The MCPA operates at full power if the system DC supply is within 26 to 30 VDC. The MCPA shuts down if the applied DC power is less than 21.5 VDC or greater than 30.5 VDC.
Power Distribution G3L-850-160 MCPA This page intentionally left blank.
Chapter 2 Controls and Indicators 2.1 Introduction This chapter contains descriptions of the G3L-850-160 Multi-Carrier Power Amplifier (MCPA) controls and indicators. 2.2 MCPA Controls and Indicators The location of the MCPA controls and indicators are illustrated in Figure 2-1 and listed with descriptions in Table 2-1. Multi-color LED Status Indicator OFF/ON/RESET Switch Figure 2-1 MCPA Controls and Indicators 2.2.
MCPA Controls and Indicators G3L-850-160 MCPA Table 2-1 MCPA Controls and Indicators Controls and Indicators Description Toggle Switch, Three Position RESET (Up) Resets MCPA. LED indicates boot mode (red), then turns solid green ON (Center) Enables MCPA. LED indicates solid green OFF (Down) Disables MCPA.
G3L-850-160 MCPA MCPA Controls and Indicators Table 2-2 MCPA Alarm States (Continued) Alarm Definition Alarm type/LED Auto-Recovery High Reverse Power Disables MCPA if the reverse RF output power is higher than 49 dBm for a duration of 1-minute. Minor (Yellow) during 1minute validation period then changes to Major (Red) Reverse power must be < 48.3 dBm. Exceed Maximum Voltage Disables MCPA immediately if supply DC voltage > +30.5 VDC.
MCPA Controls and Indicators G3L-850-160 MCPA Table 2-3 MCPA Connector Pinouts 2-4 Pin Function Pin Function A1 RF Input (Coaxial Contact) 8 SUMMARY_FAULT (Fault info) TTL A2 +27 VDC (Power Contact) 9 DC_ON/OFF (On/Off) A3 Ground (Power Contact) 10 PAU_RST (System Reset) TTL A4 RF Output (Coaxial Contact) 11 NC 1 TX_H (RS-485) 12 NC 2 TX_L (RS-485) 13 AMP_A0 (PAU ID) 3 GND 14 AMP_A1 (PAU ID) 4 RX_H (RS-485) 15 AMP_A2 (PAU ID) 5 RX_L (RS-485) 16 HPE 6 GND 17 PAU
Chapter 3 Installation 3.1 Introduction This chapter contains unpacking, inspection, startup and installation procedures for the G3L-850-160 Multi-Carrier Power Amplifier (MCPA). 3.2 • Review this chapter prior to equipment installation. • Review any government and local codes applicable to this installation. • Read the instructions in this Chapter and Chapter 4 before operating the equipment. Unpacking and Inspection Perform the steps in Table 3-1 to unpack and inspect the MCPA.
Initial Start-up and Operating Procedures G3L-850-160 MCPA The modular MCPA can be installed in a variety of systems. All system connections to the MCPA are made through the MCPA rear connector, no additional wiring is required. Perform the steps in Table 32 to install the MCPA. Refer to Figure 3-1 for quarter-turn fastener position and switch location. Table 3-2 MCPA Installation Step Action 1 Set MCPA OFF/ON/RESET switch to the OFF (down) position.
G3L-850-160 MCPA Initial Start-up and Operating Procedures Table 3-3 Initial Start-up Procedure Step Action 1 Verify all system input and output cables are properly connected. 2 Verify +27 VDC (+/- 1 VDC) supply is available. 3 Set MCPA OFF/ON/RESET switch to ON (center) position. 4 Allow MCPA to warm-up for a minimum of two minutes before taking power readings.
Initial Start-up and Operating Procedures G3L-850-160 MCPA This page intentionally left blank.
Chapter 4 Maintenance 4.1 Introduction This chapter contains instructions for periodic maintenance, testing and troubleshooting for the G3L850-160 Multi-Carrier Power Amplifier (MCPA). 4.2 Periodic Maintenance NOTE Check your sales order and equipment warranty before attempting to service or repair unit. Do not break seals on equipment under warranty or the warranty will be null and void. Do not return equipment for warranty or repair service until proper shipping instructions are received from factory.
Return For Service Procedures G3L-850-160 MCPA CAUTION: Do not slam the MCPA into the system during installation. Using excessive force can damage the MCPA connector. CAUTION: When removing the MCPA from the system, support the MCPA to prevent the rear of the MCPA from suddenly dropping when the guide rail disengages from the track. Dropping the MCPA can damage the rear multi-pin connector. The MCPA weighs approximately 28.60 lbs. (12.97 kg). Table 4-3 MCPA Removal and Replacement Step 4.
Chapter 5 Specifications 5.1 Multi-Carrier Power Amplifier Specifications The performance and physical specifications for the G3L-1929-160 MCPA are listed in Table 5-1. . Table 5-1 MCPA Specifications Electrical Specifications/Features Operating Frequency Band 869-894 MHz Instantaneous Bandwidth 25 MHz Air Interface GSM, EDGE,.CDMA, W-CDMA RF Output Power 160 W (Min.) with seven GSM and one EDGE signal 150 W (Min.) with any combination of EDGE, GSM, W-DCDMA. Max.
Multi-Carrier Power Amplifier Specifications G3L-850-160 MCPA Table 5-1 MCPA Specifications (Continued) Mechanical Specifications/Features Controls Three position toggle switch: OFF/ON/RESET Alarm Indication LED; Green (normal), Yellow (minor alarm), Red (Major alarm) Platform Compatibility Everest Power Amplifier (PA) will reduce power level to Harley/Python APC levels if placed in a Harley/Python subrack.
Powerwave Installation and Service Manual Corporate Headquarters Powerwave Technologies, Inc. 1801 East St. Andrew Place Santa Ana, CA 92705 USA Tel: 714-466-1000 Fax: 714-466-5800 www.powerwave.com Main European Office Antennvägen 6 SE-187 80 Täby Sweden Tel: +46 8 540 822 00 Fax: +46 8 540 823 40 Main Asia-Pacific Office 23 F Tai Yau Building 181 Johnston Road Wanchai, Hong Kong Tel: +852 2512 6123 Fax: +852 2575 4860 ©Copyright 2006, Powerwave Technologies, Inc. All Rights reserved.