User's Manual
044-05156 Rev C 54
Electrical Characteristics
Parameter Limit Unit Remarks
Inter modulation Distortion (IMD7) RX Band
(J3: RX_01) to (J4: RX_02)
-110 dBc
Measured @ 1870 MHz., 2 tones
@100W (+50dBm)/Tone at J2:
Antenna
General Specification
Max Input RF -10.0 dBm
RMS power with no damage to
DLNA
-18 dB (J1: TX) 50 ohm matched.
Input Return Loss
-18 dB (J2: Antenna) 50 ohm matched
Supply Voltage Range +20 to +30 Vdc
Supply Voltage Range 27+ 0.5 Vdc Nominal
DC Current 2 A Max.
VSWR 1.5:1 Max; Source and Load
Sample Port J5
Frequency Range 1930~1990 MHz
Loss (J1: TX port to J5: Sample Port) -55±2.5 dB N Nominal
Flatness (J1: TX port to J5: Sample Port) 2.0 dB Max
Output Return Loss (J5: Sample) -18 dB Max (50 ohm matched)
Mechanical
Connector - TX port
N-type F
1
Connector - RX Ports
SMA F
2
Connector - Antenna Port
N-type F
1
Connector - Sample Port
SMA F
1
Connector - DC power & I/O
DB15
1
Switch
Rotary 4
position
1
LED
2
Dimensions
16.12 L x 9.50 W x 1.75 H inches
(409.12 L x 241.3 W x 44.45 H mm)
Weight
9 KG (19.8 lbs)
Common Environmental characteristics
Value
Characteristic Test Conditions
Min
Max
Unit
Transportation Shock IEC 68-2-27
Transportation Bounce IEC 68-2-55
Operating Altitude
(Note 2)
- 152
4000
Meter AMSL
Operating Temperature Range - 20 +85 ºC
Storage Temperature Range - 40 +85 ºC
Operating Humidity Non-condensing 0 95 %RH
Notes:
1. Maximum ratings represent the limits beyond which damage to the device may result. Continuous operation
of the device at the maximum rating limit is prohibited.
2. Max op temp may be derated by 2 degrees C/1000 ft above 2154 meters.