User's Manual
Table Of Contents
NTUM30DA Installation & Service Manual
2-6 Data I/O Connector
The alarms and sensing connections on the amplifier are made through a 14-pin micro-fit con-
nector (figure 2-3) and are listed and described in table 2-2.
13
14
1
25
Figure 2-3 Data I/O Connector
Table 2-2 Data I/O Connector Definition
Pin Signal Description
1 Manuel control Control ON/OFF
2 GND Ground
3 PA-Enable-Actif + Control
4 PA-Enable-Actif - Control
5 PA_presence_reset Towards µcontroller
6 GND_presence_reset Ground
7 Reserved Reserved
8 GND Ground
9 Reserved Reserved
10 Reserved Reserved
11 GND Ground
12 Reserved Reserved
13 Reserved Reserved
14 UART TX+ (TRM to MCPA) Base Station Control and Alarm Signaling
15 UART TX- (TRM to MCPA) Base Station Control and Alarm Signaling
16 Reserved Reserved
17 UART RX+ (MCPA to TRM) Base Station Control and Alarm Signaling
18 UART RX- (MCPA to TRM) Base Station Control and Alarm Signaling
19 GND Ground
20 Reserved Reserved
21 Reserved Reserved
22 Reserved Reserved
23 Reserved Reserved
24 Reserved Reserved
25 Reserved Reserved
Copyright Powerwave Technologies, Inc., June 2003. All rights reserved
044-05141 Rev. A 2-3 June 2003