User's Manual
Table Of Contents
G3S-800-180-029 Installation & Service Manual
Copyright Powerwave Technologies, Inc., April 2002. All rights reserved
044-05112 Rev. A 5-5 April 2002
5-6 Field Replaceable Parts And Modules
The following parts and modules can be replaced in the field on site by a qualified technician with
experience maintaining RF power amplifiers and similar equipment:
1. G3S-800-180-029 power amplifier modules
2. Cooling fans
5-6.1 G3S-800-180-029 Power Amplifier Module
To replace a power amplifier module, proceed as follows:
1. Set both the RF ON On/Off/Reset switch and the power ON/OFF switch on the front panel of
the amplifier module to OFF.
2. Loosen two screws that secure amplifier module to subrack.
CAUTION
The amplifier is equipped with a spring clip on each side panel to prevent the amplifier
from being fully removed from the subrack via the front panel handles. When removing
the amplifier from the subrack, it is very important to support the amplifier such that the
rear of the module does not suddenly drop when it disengages from the track. A drop
such as this could damage the module or cause personal injury.
Figure 5-2 Amplifier Spring Clip Location
3. Use the handle on the front of the module, and with a steady even pressure, gently pull the
module about half way out of subrack until the spring-clips prevent the amplifier from being
removed (refer to figure 5-2).
4. Simultaneously press the front half of each spring clip towards the center of the amplifier and
resume removal of the amplifier.
Spring Clip